Unisys NX5820 Manuel D’Utilisation

Page de 176
VX1505 Servers
6–12
7017 6300–005
Table 6–9.  VX1505-BSE Processor Requirements
No. of Installed
Processors
VRMs
 Required
Terminators
 Required
Notes
1
2
3
1st processor requires 2 VRMs.
3 terminators are required (XER2400-TRM)
2
3
2
2nd processor requires 1 additional VRM.
2 terminators are required (XER2400-TRM)
3
5
1
3rd processor requires 2 additional VRMs.
1 terminator is required (XER2400-TRM)
4
6
0
4th processor requires 1 additional VRM.
No terminator is required (XER2400-TRM)
Server Components
This subsection provides ordering information for VX1505-BSE/-BSU server components
Orders for server A (server position 1) must include the following:
• 
VX1505-BSE (Table 6-10) and optional redundant power supply
• 
Processors, if any (Table 6–11)
• 
Memory packages (Table 6–12)
• 
Connection package (Table 6–13) and optional PCI Thru card
• 
Optional: User access components (Table 6–14)
Orders for server B to J (server positions 2 to 10) must include:
• 
VX1505-BSU (Same contents as VX1505-BSE, Table 6-10)
• 
Same selections as for VX1505-BSE (Table 6–11 through Table 6–15)
Note:
Up to five servers per domain; up to ten servers per dual domain system.
See Figure 6–3 for a road map on ordering VX1505 servers.