Konica Minolta BP-200 Manuel D’Utilisation

Page de 468
9
Specifying management settings
9-40
200/250/350
Spe
c
if
y
ing
 ma
nag
eme
n
t s
e
tti
ng
s
Chap
ter
 9
Specifying SMTP transmission timeout settings (mode 356)
You can specify the time until a timeout of the SMTP server connection oc-
curs when sending e-mail messages.
Factory settings
Specifying settings
The shaded cells represent the factory settings. The page numbers on the 
right refer to the descriptions of the corresponding functions.
(*)
After changing the settings, the machine must be turned off, then on again.
2
Reminder 
When turning the machine off, then on again with the main power switch, 
wait about 10 seconds to turn the machine on after turning it off.
The machine may not operate correctly if it is turned on immediately after 
being turned off.
Bit
7 6 5 4  3 2 1 0
Setting
0 1 0 0  0 0 0 0 (HEX: 40)
Bit
Description
Setting
Description
Page 
Refer-
ence
7, 6, 5, 4
Specifies the time until a 
timeout of the SMTP server 
connection occurs when 
sending e-mail messages.(*)
0001
30 seconds
---------
0010
60 seconds
0011
90 seconds
0100
120 seconds
0101
150 seconds
0110
180 seconds
0111
210 seconds
1000
240 seconds
1001
270 seconds
1010
300 seconds
Other
*Do not specify other set-
tings than the above.
3, 2, 1, 0
-----------------------------
0000
*Do not change these bits 
when specifying settings for 
this function.
---------