GeNeratOr OUtpUts/GaUGe reaDiNG
hoW to  read the  ac  ammeter  and  ac 
voltage gauges
The AC ammeter and AC voltmeter gauges are controlled 
by the AC ammeter and AC voltmeter change-over switches.
Both of these switches are located on the control panel and 
dO NOT effect the generator output. They are provided to 
help observe how much power is being supplied, produced 
at the UVWO terminals lugs.
Before taking a reading from either gauge, set the 
Voltage 
Selector Switch (Figure 16) to the position which produces 
the required voltage (For example, for 3Ø 240V, choose the 
center 3Ø 240/139V position on the voltage selector switch 
Figure 16. Voltage Selector Switch- 
240/3
Ø Position
ac voltmeter gauge reading
Place the
 AC Voltmeter Change-Over Switch (Figure 17) 
in the W-U position and observe the phase to phase voltage 
reading between the W and U terminals as indicated on 
the 
AC Voltmeter Gauge (Figure 18).
Figure 17. AC Voltmeter 
Change-Over Switch
Figure 18. AC Voltmeter Gauge 
(Volt reading on W-U Lug)
ac ammeter gauge Reading
Place the
 AC Ammeter Change-Over Switch (Figure 19) 
in the U position and observe the current reading (load 
drain) on the U terminal as indicated on the 
AC Ammeter 
Gauge (Figure 20). This process can be repeated for 
terminals V and W.
Figure 19. AC Ammeter 
Change-Over Switch
Figure 20. AC Ammeter 
(Amp reading on U Lug)
NOTICE
The 
ammeter gauge will only show a reading when 
the 
Output Terminal Lugs are connected to a load 
and in use.