Maxon Telecom MODMAX MM-6280IND Manuel D’Utilisation

Page de 70
 
 
Extended AT Commands Manual 
Page 12 of 70 
2009-06-25 
2 .   A T   I N T E R F A C E   D E S C R I P T I O N  
2.1.  Basic Integration 
The modem supports asynchronous serial communication known as RS-232. 
This chapter describes the basic integration and communication of MT2 with TE2. MT2 hereby 
defines   and TE2 means host products which can issue AT commands and handle the response 
through UART or RS-232 signalling. The popular examples of TE2 are PC’s, PDA’s and unmanned 
systems such as Data Loggers, RTU’s or PLC’s. 
2.2.  Serial Interface 
TE2’s command and MT2’s response pair is the basic interface sequence. The pairs should keep a 
pre-defined format and ignore the case of letters unless otherwise specified.   Supports 2 serial 
interfaces, UART1 and UART2. UART1 serves an AT command set with ASCII character sequence 
and UART2 as a factory diagnostic port, serves an AT command with Async-HDLC format. 
 
2.2.1. 
Pin out