Enterasys Networks SecureStack C2RPS-CHAS2 Manuel D’Utilisation

Page de 34
Connecting the PSM Cables and AC Power Cords
2-6 Installation
Connecting the PSM Cables and AC
 
Power Cords
The PSMs are connected to the SecureStack C2 Ethernet switch devices using C2RPS‐PSM 
Cables. 
To connect the PSMs, proceed as follows:
1.
Connect one end of the C2RPS‐PSM Cable (shown in 
) to the Redundant 
Power Supply connector on the switch device. Then connect the other end to the 
Redundant Power Supply connector at the rear of the PSM as shown in 
 and 
.
2.
Connect a standard AC power cord to the AC input power connector on the PSM 
shown in 
, then plug the AC power cord into the main AC power outlet. 
3.
The green Power LED on the front of the PSM will illuminate to indicate a successful 
connection. If the LED remains off, proceed as follows:
a.
Check the AC power cord connection at the AC power source and make sure the 
power source is within specification.
b. Check the AC power connection to the PSM.
c.
Swap the AC power cord with a known good one.
d. If the green LED continues to remain off, contact Enterasys Networks. Refer to 
” on page 1‐5 for instructions. Otherwise, proceed to step 4.
4.
If installing two PSM power supplies, repeat steps 1 through 3 for the second PSM.
Figure 2-3  C2RPS-PSM Cable
Figure 2-4  Power Connectors on C2RPS-PSM (rear view)
Redundant Power Supply connector 
AC power connector (rear of chassis)
AC LINE
100-240 VAC
50-60 Hz
2A MAX
Redundant Power Supply
À
Á