The.options.port.of.the.AdderView.CATxIP.
1000.can.be.used.to.connect.to.one.or.more.
optional.power.control.units..This.allows.you.to.
control.the.mains.power.being.supplied.to.the.
connected.computer(s).so.that.an.authorised.
user.can,.if.necessary,.perform.a.complete.
remote.cold.reboot.on.a.failed.system.
The.control.connector.of.the.first.power.switch.
is.attached,.via.serial.cable,.to.the.rear.panel.of.
the.AdderView.CATxIP.1000..Any.additional.power.switches.are.then.attached.
via.a.‘daisy-chain’.arrangement.to.the.first.power.switch..Each.power.switch.box.
is.then.given.a.unique.address.and.access.to.each.power.port.(8.ports.on.each.
power.switch.box).is.gained.using.a.combination.of.the.switch.box.address.and.
the.port.number..
1000.can.be.used.to.connect.to.one.or.more.
optional.power.control.units..This.allows.you.to.
control.the.mains.power.being.supplied.to.the.
connected.computer(s).so.that.an.authorised.
user.can,.if.necessary,.perform.a.complete.
remote.cold.reboot.on.a.failed.system.
The.control.connector.of.the.first.power.switch.
is.attached,.via.serial.cable,.to.the.rear.panel.of.
the.AdderView.CATxIP.1000..Any.additional.power.switches.are.then.attached.
via.a.‘daisy-chain’.arrangement.to.the.first.power.switch..Each.power.switch.box.
is.then.given.a.unique.address.and.access.to.each.power.port.(8.ports.on.each.
power.switch.box).is.gained.using.a.combination.of.the.switch.box.address.and.
the.port.number..
To connect and address the switch boxes
Note: The AdderView CATxIP 1000 unit can be powered on during this
procedure, however, the switch boxes should be switched off. The configuration
steps below are for the Adder EPS-M8 and EPS-S8 power switches. Other power
switches may require different configuration. Please refer to your power switch
documentation.
Note: The AdderView CATxIP 1000 unit can be powered on during this
procedure, however, the switch boxes should be switched off. The configuration
steps below are for the Adder EPS-M8 and EPS-S8 power switches. Other power
switches may require different configuration. Please refer to your power switch
documentation.
1. Mount.up.to.four.switch.boxes.in.positions.where.they.are.close.to.the.
computer.systems.that.they.will.control.and.not.too.distant.from.the.
AdderView.CATxIP.1000.unit.(preferably.within.2.5.metres).
AdderView.CATxIP.1000.unit.(preferably.within.2.5.metres).
2. Use.a.serial.cable.with.an.RJ9.and.a.9-pin.D-type.connector.(see.
.for.specification)..Attach.the.RJ9.plug.to.the.socket.marked.
IN
.on.the.
first.switch.box..Attach.the.other.end.to.the.socket.marked.
OPTIONS
.on.the.
AdderView.CATxIP.1000.
Power to computer
Box , port - address:
Box , port - address:
Box
Box
Box
Box
Power
switch
boxes
switch
boxes
‘Daisy-chain’
control
connections
control
connections
The.power.ports.are.connected.to.the.power.inputs.of.each.computer.system.
and.the.power.switch.box(es).are.then.connected.to.a.mains.power.supply.
IMPORTANT: Power switching devices have a maximum current rating. It is
essential to ensure that the total current drawn by the equipment connected
to the power switching device does not exceed the current rating of the power
switching device. You must also ensure that the current drawn from any mains
socket does not exceed the current rating of the mains socket.
Setting.up,.configuring.and.using.power.switching.requires.three.main.steps:
and.the.power.switch.box(es).are.then.connected.to.a.mains.power.supply.
IMPORTANT: Power switching devices have a maximum current rating. It is
essential to ensure that the total current drawn by the equipment connected
to the power switching device does not exceed the current rating of the power
switching device. You must also ensure that the current drawn from any mains
socket does not exceed the current rating of the mains socket.
Setting.up,.configuring.and.using.power.switching.requires.three.main.steps:
•. Connect.and.address.the.switch.boxes.
•.
•. Operate.power.switching.
or.the.local.
3. For.each.of.the.remaining.switch.boxes.(if.used),.use.a.serial.cable.with.RJ9.
connectors.at.both.ends.(see.
.for.specification)..Attach.one.
end.to.the.socket.marked.
OUT
.of.the.previous.box.and.the.other.end.to.the.
socket.marked.
IN
.of.the.next.box..
4. Set.the.addressing.switches.on.each.switch.box.
using.the.two.micro.switches.marked.‘Slct’.on.
the.front.panel..The.box.connected.directly.to.
the.AdderView.CATxIP.1000.is.Box.1.and.so.on,.
down.the.daisy-chain.line.to.Box.4.at.the.end.
the.front.panel..The.box.connected.directly.to.
the.AdderView.CATxIP.1000.is.Box.1.and.so.on,.
down.the.daisy-chain.line.to.Box.4.at.the.end.
5. Attach.IEC.to.IEC.power.leads.between.
each.port.and.the.power.input.socket.of.
each.computer.system.that.requires.power.
switching..Carefully.note.to.which.power.
ports,.on.which.boxes,.each.computer.system.is.connected..If.computer.
systems.have.multiple.power.inputs,.then.each.input.must.be.connected.via.
separate.ports,.which.can.be.on.the.same,.or.different.boxes.
each.computer.system.that.requires.power.
switching..Carefully.note.to.which.power.
ports,.on.which.boxes,.each.computer.system.is.connected..If.computer.
systems.have.multiple.power.inputs,.then.each.input.must.be.connected.via.
separate.ports,.which.can.be.on.the.same,.or.different.boxes.
6. Connect.each.box.to.a.suitable.mains.power.input..
Now.proceed.to.the.configuration.stage.covered.in.the.
.section.within.the.Configuration.chapter.
5V
2.0A
12
1
16
1
OPTIONS
COMPU
T
AdderView CATxIP
000 rear panel
Serial cable to first
power switch box
Box
Switch Switch .
.
1
...
Off.
Off
.
2
.
On.
Off
.
3
.
Off.
On
.
4
.
On.
On
Off = switch upwards
On = switch downwards
Switch is on the left side
On = switch downwards
Switch is on the left side
POWER
SWITCH