LOC REM OSD UPG LCK PWR
www.adder.com
KVM
only
Power control port
The.options.port.of.the.AdderView.CATxIP.
1000.can.be.used.to.connect.to.one.or.more.
optional.power.control.units..This.allows.you.to.
control.the.mains.power.being.supplied.to.the.
connected.computer(s).so.that.an.authorised.
user.can,.if.necessary,.perform.a.complete.
remote.cold.reboot.on.a.failed.system.
The.control.connector.of.the.first.power.switch.
is.attached,.via.serial.cable,.to.the.rear.panel.of.
the.AdderView.CATxIP.1000..Any.additional.power.switches.are.then.attached.
via.a.‘daisy-chain’.arrangement.to.the.first.power.switch..Each.power.switch.box.
is.then.given.a.unique.address.and.access.to.each.power.port.(8.ports.on.each.
power.switch.box).is.gained.using.a.combination.of.the.switch.box.address.and.
the.port.number..
To connect and address the switch boxes
Note: The AdderView CATxIP 1000 unit can be powered on during this 
procedure, however, the switch boxes should be switched off. The configuration 
steps below are for the Adder EPS-M8 and EPS-S8 power switches. Other power 
switches may require different configuration. Please refer to your power switch 
documentation.
1. Mount.up.to.four.switch.boxes.in.positions.where.they.are.close.to.the.
computer.systems.that.they.will.control.and.not.too.distant.from.the.
AdderView.CATxIP.1000.unit.(preferably.within.2.5.metres).
2. Use.a.serial.cable.with.an.RJ9.and.a.9-pin.D-type.connector.(see.
.for.specification)..Attach.the.RJ9.plug.to.the.socket.marked.
IN
.on.the.
first.switch.box..Attach.the.other.end.to.the.socket.marked.
OPTIONS
.on.the.
AdderView.CATxIP.1000.
Power to computer
Box , port  - address: 
Box 
Box 
Box 
Box 
Power 
switch 
boxes
‘Daisy-chain’ 
control 
connections
The.power.ports.are.connected.to.the.power.inputs.of.each.computer.system.
and.the.power.switch.box(es).are.then.connected.to.a.mains.power.supply.
IMPORTANT: Power switching devices have a maximum current rating. It is 
essential to ensure that the total current drawn by the equipment connected 
to the power switching device does not exceed the current rating of the power 
switching device. You must also ensure that the current drawn from any mains 
socket does not exceed the current rating of the mains socket.
Setting.up,.configuring.and.using.power.switching.requires.three.main.steps:
•. Connect.and.address.the.switch.boxes.
•.
•. Operate.power.switching.
or.the.local.
3. For.each.of.the.remaining.switch.boxes.(if.used),.use.a.serial.cable.with.RJ9.
connectors.at.both.ends.(see.
.for.specification)..Attach.one.
end.to.the.socket.marked.
OUT
.of.the.previous.box.and.the.other.end.to.the.
socket.marked.
IN
.of.the.next.box..
4. Set.the.addressing.switches.on.each.switch.box.
using.the.two.micro.switches.marked.‘Slct’.on.
the.front.panel..The.box.connected.directly.to.
the.AdderView.CATxIP.1000.is.Box.1.and.so.on,.
down.the.daisy-chain.line.to.Box.4.at.the.end.
5. Attach.IEC.to.IEC.power.leads.between.
each.port.and.the.power.input.socket.of.
each.computer.system.that.requires.power.
switching..Carefully.note.to.which.power.
ports,.on.which.boxes,.each.computer.system.is.connected..If.computer.
systems.have.multiple.power.inputs,.then.each.input.must.be.connected.via.
separate.ports,.which.can.be.on.the.same,.or.different.boxes.
6. Connect.each.box.to.a.suitable.mains.power.input..
Now.proceed.to.the.configuration.stage.covered.in.the.
.section.within.the.Configuration.chapter.
5V
2.0A
12
1
16
1
OPTIONS
COMPU
T
AdderView CATxIP 
000 rear panel
Serial cable to first 
power switch box
 
Box
  Switch   Switch .
.
1
...
Off.
Off
.
2
.
On.
Off
.
3
.
Off.
On
.
4
.
On.
On
Off = switch upwards
On = switch downwards
Switch  is on the left side
POWER
SWITCH