 Geo Brick Drive User Manual 
Pinouts and Software Setup 
 126 
Channel Control Registers 
X:$78Bn0, X:$78Bn4, X:$78Bn8, X:$78BnC 
where:  n=2 for axes 1-4 
 
 
 
 
 
 
 
n=3 for axes 5-8 
 
Channel 1  X:$78B20  Channel 5  X:$78B20 
Channel 2  X:$78B24  Channel 6  X:$78B34 
Channel 3  X:$78B28  Channel 7  X:$78B38 
Channel 4  X:$78B2C  Channel 8  X:$78B3C 
 
Bits  10,  12,  and  13  are  the  only  fields  to  be  configured  in  the  Channel  Control  Registers  with  the 
Yaskawa option. The rest is protocol information. This has to be done in a startup PLC to execute once on 
power up.  
 
[23:14] 
13 
12 
11 
10 
[9:0] 
Reserved 
Trig. 
Mode 
Trig. 
Enable 
 
RxData Ready/ 
SENC 
Reserved 
 
Bit 
Type  Default 
Name 
Description 
[23:14] 
0x000 
Reserved 
Reserved and always reads zero. 
[13] 
 
R/W 
Trigger Mode 
Trigger Mode to initiate communication: 
0= continuous trigger  
1= one-shot trigger 
All triggers occur at the defined Phase/Servo clock edge and 
delay setting. See Global Control register for these settings.  
[12] 
R/W 
Trigger 
Enable 
Enable trigger for serial encoder communications:  
0= disabled 
1= enabled 
This  bit  must  be  set  for  either  trigger  mode.  If  the  Trigger 
Mode  bit  is  set  for  one-shot  mode,  the  hardware  will 
automatically clear this bit after the trigger occurs. 
[11] 
R/W 
Reserved 
Reserved and always reads zero. 
[10] 
RxData Ready 
This read-only bit provides the received data status. It is low 
while  the  interface  logic  is  communicating  (busy)  with  the 
serial encoder. It is high when all the data has been received 
and processed. 
SENC_MODE 
This  write-only  bit  is  used  to  enable  the  output  drivers  for 
the  SENC_SDO,  SENC_CLK,  SENC_ENA  pins  for  each 
respective  channel.  It  also  directly  drives  the  respective 
SENC_MODE pin for each channel. 
[09:00] 
0x0 
Reserved 
Reserved and always reads zero.