Breckwell TRADITION SERIES P23 P23FSL Manuel D’Utilisation

Page de 31
Equivalent Vent Length (EVL) 
The longer the run of pipe in your installation (both with insert and 
freestanding models), the more restriction there is in the system. 
Therefore, larger diameter pipe should be used. 
 
Use 4” pipe if you have more than 15 feet of equivalent vent 
length. 
 
Horizontal runs shall not exceed 10 feet of EVL. 
 
Recommended vertical runs to be a minimum of 8 feet. 
 
To calculate EVL, use the following conversions: 
90º elbow or “T”  
= 5 equivalent feet 
45º elbow 
 
= 3 equivalent feet 
Horizontal Pipe Run 
= 1 equivalent foot per actual foot 
Vertical Pipe Run 
= 0.5 equivalent foot per actual foot 
NOTE: At altitudes above 3,000 feet, we suggest the use of 4” 
diameter vent at an EVL of 7 feet or more. 
FREESTANDING INSTALLATIONS 
A. 
ASSEMBLING PEDESTAL OR LEG SET (Refer to figure 8) 
If using a pedestal, follow the instructions inside the Breckwell 
P23 Pedestal w/ Ashpan.  
If using cast legs, follow the instructions inside the Breckwell P23 
Leg Set w/ Ashpan. 
Legs are installed by inserting the four bolts provided in the kit 
into the four holes in the bottom plate of the stove at each corner 
from the top, thread on the nuts from the bottom and tighten. 
 
 
 
 
 
FIGURE 8 
INSTALLATION