Whirlpool AD70USS Manuel Du Propriétaire

Page de 20
4
DEHUMIDIFIER USE
Setting the Controls (Control Types 1 and 2 Only)
Starting/Stopping the Dehumidifier 
NOTE: Before turning on the dehumidifier, be sure that the 
bucket is empty and fits all the way into the dehumidifier.
Control Type 1
NOTES: 
Minimum operating temperature is 65ºF (18ºC) for model 
AD25B.
Minimum operating temperature is 55ºF (13ºC) for model 
AD25D.
Control Type 2
NOTE: Minimum operating temperature is 55ºF (13ºC).
1. Plug into a grounded 3 prong outlet.
2. To turn on dehumidifier, turn DRYNESS CONTROL clockwise. 
IMPORTANT: If the Empty/Adjust Bucket light comes on, the 
dehumidifier will not operate. Empty or adjust bucket.
3. To turn off dehumidifier, turn DRYNESS CONTROL 
counterclockwise to OFF.
Empty/Adjust Bucket Light
If this light is on, the dehumidifier is not running. This light 
indicates that you need to check:
If the bucket is full, empty and reinstall bucket.
If the bucket is not in position, remove the bucket and 
reinstall. Make sure the bucket fits all the way into the 
dehumidifier and the light is off, or dehumidifier will not run.
Fan Speed (Control Type 2 Models Only)
The Fan Speed controls fan operation
High—for faster moisture removal
Low—for quieter moisture removal
Dryness Control
The Dryness Control regulates the amount of moisture in the 
room. Turn the control knob clockwise for more drying. Turn the 
control knob counterclockwise for less drying. Turn the control 
knob to “Dry” to maintain average humidity conditions.
NOTES: 
For the first few days of use, turn the DRYNESS CONTROL 
clockwise to CONTINUOUS RUN to remove extra moisture 
from the furnishings as well as the room air. 
For all models except AD25B, the Deicer will turn off the 
compressor if a low temperature condition exists. Turning the 
Dryness Control will not increase or decrease the amount of 
moisture removed. Compressor operation will resume when 
the low temperature condition no longer exists.
A. Light glows, indicating the bucket is full or is not in correct position.
B. Adjusts amount of moisture removed from room.
A. Light glows, indicating the bucket is full or is not in correct position.
B. Adjusts amount of moisture removed from room.
C. Selects fan speed.
A
B
A
C
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING