Vent system chart
NOTE: Side exhaust installations add a 90º turn inside the dryer. 
To determine maximum exhaust length, add one 90º turn to the 
chart.
Install Vent System
1. Install exhaust hood. Use caulking compound to seal exterior 
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust 
hood. Secure vent to exhaust hood with 4" (102 mm) clamp.
3. Run vent to dryer location. Use the straightest path possible. 
See “Determine vent path” in “Plan Vent System.” Avoid 90º 
turns. Use clamps to seal all joints. Do not use duct tape, 
screws, or other fastening devices that extend into the interior 
of the vent to secure the vent, because they can catch lint.
Level Washer/Dryer
Properly leveling your washer/dryer avoids excessive noise and 
vibration.
1. Check the levelness of the washer/dryer by placing a level 
on the top edge of the washer, first side to side, then front 
to back.
2. If the washer/dryer is not level, prop up the front with a wood 
block and adjust the feet up or down as necessary. Remove 
wood block and lower washer/dryer. Repeat this step until the 
washer/dryer is level.
Make Gas Connection
1. Remove the red cap from the flexible gas connector.
2. Remove the ½" NPT adapter from the flexible gas connector 
(it will be necessary to use two adjustable wrenches).
3. Install the adapter on the ½" rigid gas supply pipe using pipe-
joint compound.
NOTE: For LP gas connections, you must use pipe-joint 
compound resistant to the action of LP gas. Do not use 
TEFLON
®†
 tape.
4. Attach the flexible gas connector to the ½" NPT adapter. 
Do not use pipe-joint compound for this connection. 
There should be a natural loop in the flexible gas connector. 
The flexible gas connector must not be twisted, kinked, or 
attached with any sharp bends.
5. All connections must be wrench tightened.
6. Open the shutoff valve in the supply. The valve is open when 
the handle is parallel to the gas pipe.
7. Test all connections by brushing on an approved noncorrosive 
leak-detection solution. Bubbles will show a leak. Correct any 
leak found.
Connect Vent
1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet 
in washer/dryer. If connecting to existing vent, make sure the 
vent is clean. The vent must fit over the exhaust outlet and 
inside the exhaust hood. Make sure the vent is secured to 
exhaust hood with a 4" (102 mm) clamp.
2. Move washer/dryer into its final location. Do not crush or kink 
vent. Make sure washer/dryer is level.
3. Check that there are no kinks in the flexible gas line.
Number of 
90º turns 
or elbows 
Type of Vent
Box or 
Louvered 
hoods
Angled 
hoods
0
Rigid metal
43 ft (13.1 m)
36 ft (11.0 m)
1
Rigid metal
33 ft (10.1 m)
26 ft (7.9 m)
2
Rigid metal
23 ft (7.0 m)
16 ft (4.9 m)
A. ½" rigid gas supply pipe
B. Use pipe-joint compound.
C. ½" NPT adapter
D. Do not use pipe-joint compound.
E. Flexible gas connector
A. Closed valve
B. Open valve
B
A
C
D
E
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A
A