Must include a shutoff valve:
An individual shutoff valve must be installed within 
six (6) feet (1.8 m) of the washer/dryer in accordance with 
the National Fuel Gas Code, ANSI Z223.1/NFPA 54. The 
location should be easy to reach for opening and closing.
Burner input requirements:
Elevations up to 10,000 ft (3,048 m):
The design of this washer/dryer is certified by CSA 
International for use at altitudes up to 10,000 ft (3,048 m) 
above sea level at the Btu rating indicated on the model/serial 
number plate. Burner input adjustments are not required when 
the dryer is operated up to this elevation.
Elevations above 10,000 ft (3,048 m):
When installed above 10,000 ft (3,048 m), a 4% reduction of 
the burner Btu rating shown on the model/serial number plate 
is required for each 1,000 ft (305 m) increase in elevation.
Gas supply pressure testing
The washer/dryer must be disconnected from the gas supply 
piping system during pressure testing at pressures greater 
than ½ psi.
Dryer gas connection
This washer/dryer is equipped with its own permanent, 
flexible gas connector, design-certified by CSA International, 
for connecting the washer/dryer to the gas supply line.
Flexible gas connector
Venting Requirements
WARNING: 
To reduce the risk of fire, this washer/dryer 
MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, attic, crawlspace, or a concealed space 
of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure 
exhaust hood is not plugged with lint. 
Replace any plastic or metal foil vent with rigid or flexible 
heavy metal vent.
Review Vent system chart. Modify existing vent system if 
necessary to achieve the best drying performance. Only rigid 
or flexible metal vent shall be used for exhausting. 
If this is a new vent system 
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (102 mm) heavy metal exhaust vent and clamps must be 
used. DURASAFE™ venting products are recommended.
DURASAFE™ vent products can be purchased from your 
dealer or by calling Whirlpool Parts and Accessories. For more 
information, see the “Assistance or Service” section of the 
Washer/Dryer User Instructions.
Rigid metal vent
For best drying performance, rigid metal vents are 
recommended.
Rigid metal vent is recommended to avoid crushing and 
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for 
cleaning.
Flexible metal vent must be fully extended and supported 
when the dryer is in its final location. 
A. Gas shutoff valve
B. " NPT minimum plugged tapping
C. ½" NPT gas supply line
D. Gas supply line coupling 34" (864 mm) min. 
to 37" (940 mm) max. from floor
A
B
C
D
4" (102 mm) heavy metal exhaust vent
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death 
or fire.