VAX RS 232C Manuel D’Utilisation

Page de 24
Page 4 of 24 
3. COMMAND CONFIGURATION 
 
•                                                                                                                                                                                   
•                              is in the range of 80H to FFH.                                and              are in the 
range of 00H to 7FH. 
• Data length (N) refers to the length of the subsequent data of Data 1 to Data N. 
• If received data contains more byte data than the Data length, these exceeding data are 
abandoned. 
• If a next command received contains byte data shorter than the Data length, the previous 
command is abandoned. 
 
4. TRANSMISSION DATA AFTER COMMAND RECEPTION 
 
When normal data is received, the same data as the reception data is to be transmitted.   
Example: 91H, 03H, 00H, 00H, 00H (Reception data) 
     
       91H, 03H, 00H, 00H, 00H (Transmission data) 
 
When channel data is received and the data is outside of the range, the data is to be 
inverted and transmitted.   
Example: 91H, 03H, 00H, 08H, 00H (Reception data) 
         
              91H, 03H, 00H, 77H, 00H (Transmission data) 
 
When abnormal data is received, the data is to be inverted and transmitted. 
Example: 91H, 03H, 00H, 00H, 6AH (Reception data) 
         
              91H, 03H, 00H, 00H, 15H (Transmission data) 
 
When data other than channel data is received and the data is outside of the range, no data 
is transmitted. 
Example: 91H, 03H, 05H, 00H, 6AH (Reception data) 
         
              No response 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5. CONTROL COMMAND AND SETTING VALUE 
Command 
Data length
 (N) 
Data 1
Data 2
Data N 
Data   
Data
length 
Command