REPLACING THE PUMP TUBING
The pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, 
the tubes are a wear item and must be replaced periodically. How long the tube last is dependent on usage and 
properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a weak mixed 
beverage. Bunn-O-Matic recommends replacing the Pump Tubing a minimum of once every 6 months or 
sooner if warranted. 
Refer to the Tube Replacement Instruction inside the Cabinet door.
Note: To avoid concentrate spills, rinse the pump tubing with warm tap water prior to removing the tubes, (Refer 
to steps 1 - 4 of the Weekly Sanitizing instructions). 
1.  Disconnect pump tube connector from product box by turning connector counterclockwise. Repeat for other 
pump and product box.
2.  Remove product box from product shelf, and remove product shelf from machine by sliding forward.
3.  Refer to INSTALLING PUMP TUBING, page 8.
39328.3 012113
PREVENTIVE MAINTENANCE
Bunn-O-Matic
®
 Corporation recommends that preventive maintenance be performed at regular intervals. Main-
tenance should be performed by a qualified service technician. For Technical Service, contact Bunn-O-Matic
®
 
Corporation at 1-800-286-6070.
NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by 
warranty.