Znyx Networks ZX470 Series Manuel D’Utilisation

Page de 11
 
ZNYX NetBlaster 470 Series cPCI Fast Ethernet Adapter 
User’s Guide  
 
 
Page 8 
Troubleshooting 
1.  Make sure the board is securely seated in the slot. 
 
2.  Observe the LED’s. Each port on the ZX478 has a LINK (green) LED and an ACTIVITY 
(amber) LED. The green LED illuminates upon successfully establishing a link. The amber 
LED illuminates during transmit/receive activity. Note: In most cases, the driver must be 
properly loaded and configured to bring up the link. It is off if there is no link established.  
 
Each ZX478 also has LED's for Power, Operational, Internal and External fault indicators. 
The status LED is duplicated on both the front and rear panels. The front panel also 
includes an LED indicating continuity with the Rear-Transition Module. The front panel 
also includes the industry-standard blue LED next to the bottom Hot-Swap ejector tab. The 
LED's are defined by the following table: 
 
Label Color 
Function 
Power Green 
ON 
indicates 
power. 
Operational 
Green 
ON indicates driver loaded and 
board has passed internal tests. 
Rear Panel 
Green 
ON indicates electrical 
continuity between adapter and 
rear-transition module. 
Internal Fault 
Amber 
ON indicates a failure of the 
internal tests. 
External Fault 
Amber 
ON indicates a failure external 
to the adapter- inability to 
establish link on a configured 
port, or another connectivity 
problem external to the adapter. 
Hot Swap 
Blue 
ON during removal/insertion 
of adapter, signifying system 
readiness for transition. 
 
 
3.  Refer to operating system specific documentation to evaluate any error messages or logs 
when the driver is loaded.