1FW6160-xxxxx-xxxx
Data sheet 1FW6160-xxB05-xxxx
Table 14- 13 1FW6160-xxB05-1Jxx, 1FW6160-xxB05-2Jxx, 1FW6160-xxB05-5Gxx
Technical data
1FW6160
1FW6160
Symbol
Unit
-xxB05-1Jxx -xxB05-2Jxx -xxB05-5Gxx
Boundary conditions
DC link voltages
U
ZK
V
600
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
35
Rated temperature of winding
T
N
°C
130
130
130
Rated data
Rated torque
M
N
Nm
431
404
314
Rated current
I
N
A
16
24
36
Maximum speed at rated torque
n
MAX,MN
rpm
140
250
590
Rated power dissipation
P
V,N
kW
2.84
2.85
2.88
Limit data
Maximum torque
M
MAX
Nm
716
716
716
Maximum current
I
MAX
A
31
49
98
Electric power of motor at M
MAX
P
EL,MAX
kW
15.1
20
33.1
Maximum speed at maximum torque
n
MAX,MMAX
rpm
84
150
320
No-load speed
n
MAX,0
rpm
240
380
750
Torque at n = 1 [rpm]
M
0
Nm
467
467
467
Current at M
0
and n = 1 [rpm]
I
0
A
17
28
56
Thermal static torque
M
0
*
Nm
330
330
330
Thermal stall current
I
0
*
A
12
19
38
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
26.6
17
8.51
Voltage constant
k
E
V/(1000/min)
1608
1029
514.5
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
8.96
8.95
8.91
Thermal time constant
t
TH
s
180
180
180
No. of pole pairs
p
-
35
35
35
Cogging torque
M
COG
Nm
2.3
2.3
2.3
Stator mass
m
S
kg
27.2
27.2
27.2
Rotor mass
m
L
kg
9.1
9.1
9.1
Rotor moment of inertia
J
L
10
-2
kgm
2
19
19
19
Phase resistance of winding at 20 °C
R
STR, 20
Ω
2.11
0.866
0.218
Phase inductance of winding
L
STR
mH
18.1
7.4
1.9
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
2.13
2.14
2.16
Recommended minimum volume flow rate
H,MIN
l/min
3.8
3.8
3.8
1FW6 Built-in torque motors
228
Configuration Manual, 05/2009, 6SN1197-0AD00-0BP7