Sierra FLAT-TRAKTM 780S Manuel D’Utilisation

Page de 48
Appendix A Specifications
Series 780S Instruction Manual
A-2
IM-78S-B
Leak Integrity
1 X 10
–4
 atm cc/sec of helium maximum
Power Requirements
18 to 30 VDC (regulated), 625 mA maximum
100 to 240 VAC , 50/60 Hz, 15 watts maximum*
*
not available on NEMA 4X enclosures
Output Signal
Linear 0-5 VDC or 0-10 VDC proportional to mass flow rate, 1000 Ohms mini-
mum load resistance, or Linear 4-20 mA proportional to mass flow rate, 700
Ohms maximum resistance (power supply dependent), optically isolated
Alarms
User-adjustable low, high or window alarms
Deadband adjustable with Smart Interface™ software
Relay rating...............Maximum 42 VAC or 42 VDC, 140 mA
Displays
Alphanumeric 2 x 12 digit backlit LCD
Adjustable variables via on-board membrane buttons or with Smart Interface™ software
Adjustable variables...............Full scale adjustment (50 to 100%)
Time response (0.1 to 7.2 seconds)
Correction factor setting (0.5 to 5)
Zero and span adjustments
Totalizer
Eight digits (99,999,999) in engineering units
Software
Smart Interface Windows™-based software, minimum 8 MB of RAM,
preferred 16 MB of RAM, RS-232 communication
Physical Specifications
Wetted Materials
316L stainless steel, Schedule 40 pipe flow body, Carbon steel flow bodies
available in some sizes
Enclosure
Hazardous-Area enclosure (IP67) and NEMA 4X (IP65) powder-coated cast aluminum
Electrical Connections
Two 3/4 inch NPT
Hazardous-Area enclosure (IP67)
One 1/2 inch NPT
NEMA 4X enclosure (IP65)
Certifications*
CE (all enclosures)
CSA (Explosion proof for Class I, Division 1, Groups B, C, D)
EEx (EEx dIIC T6...T2) Cenelec
FM (Explosion proof for Class I, Division 1, Groups B, C, D)
*Certifications pending, contact factory