RTS SSA-424 Manuel D’Utilisation

Page de 18
SSA-424 U
SER
 M
ANUAL
 13
2.5.2
C
ALL
 S
IGNAL
 C
ONNECTIONS
 
FOR
 O
THER
 4-
W
IRE
 C
OMMUNICATON
 S
YSTEMS
2.5.2.1 4-W
IRE
 C
ALL
 S
END
 
AND
 C
ALL
 E
NABLE
/I
NHIBIT
The SSA-424 accepts a switch-contact input from the
4-wire system and then generates a call signal output
to the 2-wire system.  The SSA-424 also accepts an
optional switch contact input to enable or inhibit call
signaling between the 4-wire and 2-wire systems.
Figure 6 shows the typical connections.
2.5.2.2 4-W
IRE
 C
ALL
 R
ECEIVE
The SSA-424 receives call signals from the 2-wire
system, then converts this to relay contact closure for
use as a 4-wire call receive indication.  The SSA-424
also provides +5 VDC which can be connected to the
relay contacts to generate a DC output signal instead
of a contact closure.  Connections for simple contact
closure and DC output signal are shown in Figure 7.
The SSA-424 power indicator flashes
whenever a call signal is received from either
2-wire line.  This can be used as an incoming
call indication for the 4-wire system, if
desired, and the level display should provide
an indication of which line is calling.
COMMON
4-WIRE CALL SEND
CALL ENABLE/INHIBIT
1
5
4
3
2
6
7
8
9
DB9F
(View from solder or crimp side)
CONNECTOR PIN NUMBERS
CLEAR-COM APPLICATION NOTE:
IF A CALL ENABLE/INHIBIT
SWITCH IS NOT USED, A JUMPER
MUST BE INSTALLED TO ENABLE
CALL SIGNALING. THE JUMPER IS
NOT REQUIRED FOR ANY OTHER
APPLICATION.
10 Ohm
PIN 4
AUX
CONNECTOR
(SYSTEM A OR B)
PIN 8
PIN 5
PIN 3
PIN 9
5 VDC
DC COMMON
1
5
4
3
2
6
7
8
9
TO SSA-424 AUX CONNECTOR
DB9F CABLE
(View from solder or crimp side)
CONNECTOR PIN NUMBERS
TO 4-WIRE SYSTEM
DB9F CABLE
(View from solder or crimp side)
CONNECTOR PIN NUMBERS
1
5
4
3
2
6
7
8 9
TO 4-WIRE + INPUT
TO 4-WIRE COMMON
TO SSA-424
AUX CONNECTOR
(SYSTEM A OR B)
SSA-424 INTERNAL CIRCUIT FOR CALL SIGNAL
OUTPUT TO 4-WIRE INTERCOM SYSTEM
+5VDC SIGNAL TO 4-WIRE
SYSTEM WHEN 2-WIRE  SYSTEM CALLS
OUTPUT SHORTS TO COMMON FOR NO CALL
SIMPLE SWITCH CONTACT CLOSURE TO 4-WIRE
SYSTEM WHEN 2-WIRE  SYSTEM CALLS
OPEN CIRCUIT FOR NO CALL
Figure 6.  Typical call send and call enable/inhibit connections
for a 4-wire intercom system.
Figure 7.  Call signal connections for a 4-wire intercom system
other than ADAM, ADAM CS, and Zeus.