   Installation
To ensure that critical air gaps are 
maintained under the appliance, we 
recommend that this appliance be 
mounted on a solid base and that the 
feet do not sink into any carpeting or 
soft flooring. 
The kitchen floor must be able to carry 
the weight of the appliance plus the 
additional weight of the cookware, 
bakeware and food. 
• 
If an appliance hood is to be fitted, 
refer to the manufacturer's 
instructions regarding fixing height. 
• 
The appliance corresponds to device 
class 1, i.e., it may be placed with the 
rear and one side to kitchen walls, 
kitchen furniture or equipment of any 
size.  The kitchen furniture or 
equipment on the other side may 
only be of the same size or smaller. 
• 
Any kitchen furniture next to the 
appliance must be heat-resistant 
(212°F minimum). 
 
Room ventilation 
The air for combustion is taken from the 
room air and the exhaust gases are 
emitted directly into the room. 
Good room ventilation is essential for 
safe operation of your appliance.  If 
there is no window or door available 
for room ventilation, extra ventilation 
must be installed. 
Do not install this appliance in a room 
below ground level unless it is open 
to ground level on at least one side.  
Failure to install correctly is 
dangerous and could result in 
prosecution. 
Prolonged intensive use of the 
appliance may call for additional 
ventilation, for example, the opening 
of a window or the use of a 
permanent fixed mechanical 
ventilation system such as an 
extractor fan or range hood that 
ventilates to the outside. 
Room size 
Ventilation opening 
Smaller than 180 ft
3
 
Min 15½ in
2
 
180 ft
3
 to 350 ft
3
 
Min 8 in
2
 
Greater than 350 ft
3
 
Not required 
In cellar or basement 
Min 10 in
2
 
Be sure your appliance is properly 
installed and grounded by a qualified 
technician in accordance with the 
National Fuel Gas Code ANSI Z223. - 
latest edition, or in Canada, CAN/CGA 
B149.1 and CAN/CGA B149.2, and 
National Electrical Code ANSI/NFPA 
No.70 - latest edition, or in Canada, 
CSA Standard C22.1, Canadian 
Electrical Code, Part 1 and local code 
requirements. 
 
Installation and Connection 
   IMPORTANT:
  Do not install the 
appliance next to refrigerators or 
freezers.  The heat emitted by the 
appliance will lead to an increased 
energy consumption of cooling 
appliances. 
• 
For installation, the appliance must 
be connected in accordance with all 
local electrical and/or gas regulations. 
   CAUTION:
  Unit is heavy and 
requires at least two persons or 
proper equipment to move. 
 
 
10