Summit PRO24G Manuel D’Utilisation

Page de 37
 
 
Test Broil Burner Flame.  While the 
burner is lit, inspect the flame.  See 
flame figures below for proper flame 
characteristics.  If the flame burns 
completely or mostly yellow, adjust the 
broil burner air shutter. 
Replace oven bottom cover.  Slide cover 
into place and replace two rear thumb 
screws. 
Flame Characteristics 
Yellow flames: 
Further adjustment is required. 
Yellow tips on outer cones: 
Normal for LP gas. 
Soft blue flames: 
Normal for natural gas. 
If the flame is completely or mostly 
yellow, verify that the regulator is set for 
the correct fuel.  After adjustment, 
retest. 
Some yellow streaking is normal during 
initial start-up.  Allow unit to operate 4-5 
minutes and re-evaluate before making 
adjustments. 
Call Service if: 
1. Any of the burners do not light. 
2. The broiler burner or bake burner 
flame goes out before reaching 
350°F. 
3. Any of the burners continues to burn 
yellow. 
If flame adjustment is necessary, 
continue to next page.  Otherwise, 
installation is complete at this point. 
Gas Conversion 
This appliance can be used with LP gas 
and natural gas.  It is shipped from the 
factory adjusted for use with natural gas.  
Conversion orifices are located in the 
conversion kit.  Follow the instructions 
packed with the orifices for gas 
conversion. 
      CAUTION:
  Risk of explosion! 
Before starting any work on the gas 
installation, please shut off the gas 
supply. 
In order to change your appliance's gas 
type, change all injectors and make 
flame adjustment for all valves at 
reduced flow rate position. 
Exchange injector for the burners 
1. Take off burner cap and burner body. 
2. Unscrew injectors. 
3. Fit new injectors. 
4. Check all connections for secure 
fitting and tightness. 
      NOTICE 
New injectors have their position 
marked on their packing, or pressure 
table on page 34 can be referred to. 
 
 
 
 
 
1  Flame failure device 
2  Spark plug 
3  Injector 
4  Burner 
       CAUTION: 
Unless there is an abnormal condition, 
do not attempt to remove the gas 
burner taps.  You must call an 
authorized service agent if it is 
necessary to change the taps. 
Reduced gas flow rate setting for 
range taps 
1. Ignite the burner that is to be adjusted 
and turn the knob to the reduced 
position. 
 
 
 
 
17