Gaggenau AL400721 Brochure

Page de 356
Ventilation appliances
225
    
   A   R 401 131
 
   Stainless  steel
  Max. air output 850 m³/h
  Outside  wall  mounting
  Air  extraction
     A   R 401 140
 
   Stainless  steel
  Max. air output 1,100 m³/h
  Outside  wall  mounting
  Air  extraction
        Necessary  installation  accessories
    A   D 702 052
 
  Telescopic  wall-duct
 DN  200  cylindrical
         Installation  accessories
    A   A 401 910
 
  Roof installation set for remote fan unit 
AR 401 for slanted roof from 10 °
      A   D 702 042
 
  Pipe adapter from DN 200 circular to 
DN 150/125  circular
   Fitting to DN 150 or 125 by cutting off 
the diameters not needed.
       Special  accessories
    A   A 401 400
 
  Air outlet cover stainless steel
 For  AR 401 130/140
     A   A 401 610
 
  Silencer for air outlet of AR 401
 Stainless  steel
  Not to be combined with air outlet 
cover  AA 401 400
       A   A 401 910
 
  Roof installation set for remote fan unit 
AR 401 for slanted roof from 10 °
        Installation  accessories  for  the  air 
recirculation ducts you will find at the 
pages     236–239 .
      Remote  fan  unit
  A   R 401 
 
–    AR 401 140 for maximum output for 
downdraft ventilation and motorless 
hoods
 
– Outside installation allows lower 
noise level in the kitchen
 
–   To be combined with motorless 
hoods, downdrafts or ceiling 
ventilation
     Output
  Performance output level 3/4:
Air output according to DIN EN 61591.
Sound power and sound pressure 
depending on built-in situation.
  AR 401 131, NW 200
  590  /  850  m³/h.
  
  AR 401 140, NW 200
860 / 1,100 m³/h.
   
  For the characteristics of each output 
level with/without intensive mode 
please refer to the table with the 
respective motorless ventilation 
products.
     Features
  Complete stainless steel housing.
  Pipe connections air intake: 1 x DN 200 
cylindrical.
    Planning  notes
  When installing a ventilation hood with 
air extraction mode and a chimney-
vented fireplace, the hood's power 
supply line needs a suitable safety 
switch.
  Roof installation with roof installation 
set AD 401 910 and telescopic wall 
duct AD 702 052 in slanted roofs with 
angle of minimal 10 °.
  For maximum duct lengths use 
Gaggenau flat rectangular ducts AD 8… 
or Naber-System Compair flow. Other 
flat ducts are not permitted!
  For noise optimisation, use the silencer 
SD 011 050.
  For details of the remote fan unit's 
effective air output in combination with 
a hood or downdraft, refer to the table 
section.
    Connection
  Fan  output   355/520   W .
  Connecting  cable  1.05  m.
  Extension  cable  5  m.