5  FINAL PROCEDURES 
 
   
 
  Having replaced the injectors, remount the flame spreaders and caps of the burners and the racks. 
 
   
Once you have adjusted the appliance for use with a different gas from the factory-set one, replace 
 
the gas setting label on the appliance with the one corresponding to the new gas. The label is placed 
inside the case containing the injectors. 
 
 
   
 
 
5.1  Adjusting the minimum setting of hob burners for natural gas 
 
   
 
  Light the burner and turn it to the minimum position   . Extract the gas tap 
knob and turn the adjustment screw at the side of the tap rod until the 
correct minimum flame is achieved. 
Refit the knob and verify that the burner flame is stable (turning the knob
rapidly from the maximum to the minimum position the flame must not go
out). Repeat the operation on all the gas taps. 
 
 
   
For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and 
 
to activate the safety device. 
 
 
   
 
 
5.2  Regulation of the hob burner minimum level for ULPG 
 
   
  In order to adjust the minimum with ULPG, the screw at the side of the tap rod must be turned 
clockwise all the way. The bypass diameters for each individual burner are shown in paragraph "3.2 
Burner and nozzle characteristics table". Once the regulation has been completed, restore the seal 
on the by-passes using paint or similar materials. 
 
 
   
 
 
5.3  Wall fixing 
 
   
 
 
•  Stretch out the chain attached to the cooker horizontally so that the other end touches the wall. 
•  Mark the wall in the position where the hole is to be drilled. 
•  Drill the hole, insert the finned dowels and attach the chain. 
•  Move the cooker up against the wall.