Netcomm NCT240 Manuel D’Utilisation

Page de 38
NetComm NCT240 Installation Guide                                                   Release 1.0 
 
Pin MDI-X 
Assignment 
MDI 
Assignment 
Input Receive Data +
 
Output Transmit Data +
 
Input Receive Data -
 
Output Transmit Data -
 
Output Transmit Data +
 
Input Receive Data +
 
Output Transmit Data -
 
Input Receive Data -
 
 
Note: 
Auto-negotiation must be enabled for automatic MDI/MDI-X pinout configuration. 
 
1000BASE-T Pin Assignments 
1000BASE-T ports support automatic MDI/MDI-X operation, so you can use straight-through cables for 
all network connections to PCs or servers, or to other switches or hubs. The table below shows the 
1000BASE-T MDI and MDI-X port pinouts. These ports require that all four pairs of wires be connected. 
Note that for 1000BASE-T operation, all four pairs of wires are used for both transmit and receive. Use 
100-ohm Category 5, 5e or better unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for 
1000BASE-T connections. Also be sure that the length of any twisted-pair connection does not exceed 100 
meters (328 feet). 
Pin 
MDI Signal Name 
MDI-X Signal Name 
Transmit Data plus (TD1+)
 
Transmit Data plus (TD2 +)
 
Receive Data minus (RD1-)
 
Receive Data minus (RD2-)
 
Transmit Data plus (TD2+)
 
Transmit Data plus (TD1+)
 
Transmit Data plus (TD3+)
 
Transmit Data plus (TD4+)
 
Receive Data minus (RD3-)
 
Receive Data minus (RD4-)
 
Receive Data minus (RD2-)
 
Receive Data minus (RD1-)
 
Transmit Data plus (TD4+)
 
Transmit Data plus (TD3+)
 
Receive Data minus (RD4-)
 
Receive Data minus (RD3-)
 
 
RJ-21 Port Pin Assignments 
The PBX/MDF connector is designed to aggregate 24 POTS/ISDN ports. Each wire pair must be 
attached to the RJ-21 connector in a specific orientation detailed below. The following table shows the pin 
assignments. 
 
29