37
SMF Parameter Set 
System Exclusive Format
Data Format 
Bulk dumping SMF data transfers the data with a 128-byte header appended as shown below. The header data starts with 
an 8-byte file name, which is displayed by this Model after receipt. 
Field
Value
01
SYSEX
F0
02
MAN
44
03
MOD
11,02
04
dev
Either 00 to 1F, or 7F
05
act
04(HDS), 05(HDR), 07(Control)
06
cat
SMF = 10
07
prm
00-7F
08
ilen/dlen See "IV This Model's System Exclusive Messages".
09
ps
Indicates the SMF number being transferred. 
For details, see "39 About Parameter Set (PS) numbers".
10
index
See "IV This Model's System Exclusive Messages".
11
data
See "IV This Model's System Exclusive Messages".
12
sum
See "IV This Model's System Exclusive Messages".
13
EOX
F7
Header 128Bytes
Name 8Bytes
Reserved 120Bytes