RAD Data comm IPmux-11 Manuel D’Utilisation

Page de 148
Chapter 2  Installation and Setup 
Installation and Operation Manual 
2-4 
Connecting IPmux-11 to Power
 
IPmux-11 Ver. 2.00 
2.6  Connecting to the External Clock Source 
IPmux-11 is connected to the external clock source via a balanced RJ-45 
connector designated EXT CLK. Refer t
 for the connector pinout. 
CONTROL
EXT CLK
E1
ETH
1
2
3
SET 
DEF
 
Figure 2-5.  EXT CLK Connector 
 
To connect to the external clock source: 
•  Connect IPmux-11 to the external E1 or T1 clock source using an appropriate 
cable. 
2.7  Connecting to the ASCII Terminal 
IPmux-11 is connected to an ASCII terminal via a 9-pin D-type female connector 
designated CONTROL. Refer to 
 for the connector pinout. 
CONTROL
EXT CLK
E1
ETH
1
2
3
SET 
DEF
 
Figure 2-6.  CONTROL Connector 
 
To connect to an ASCII terminal: 
1.  Connect the male 9-pin D-type connector of CBL-DB9F-DB9M-STR straight 
cable available from RAD to the CONTROL connector. 
2.  Connect the other connector of the CBL-DB9F-DB9M-STR cable to an ASCII 
terminal. 
2.8  Connecting IPmux-11 to Power  
IPmux-11 accepts either 110–240 VAC or -48/-60 VDC power through the same 
power inlet.