RAD Data comm IPmux-11 Manuel D’Utilisation

Page de 148
Installation and Operation Manual 
Chapter 4  Configuration 
IPmux-11 Ver. 2.00 
Configuring IPmux-11 for Operation 
4-11 
 
To select the baud rate: 
1.  From the System menu (
), select Control port
The Control Port menu is displayed (see 
2.  From the Control Port menu, select Baud rate, and configure baud rate of the 
IPmux-11 terminal control port to the desired value (9600, 19200, 38400, 
57600 or 11520 bps). 
Configuration>System>Control port 
   Data bits                         (8) 
   Parity                        >   (None) 
   Stop bits                         (1) 
   Flow control                  >   (None) 
1. Baud rate (bps)               >   (115200) 
 
 
Please select item <1 to 1> 
ESC-prev.menu; !-main menu; &-exit                                   1 Mngr/s 
Figure 4-11.  Control Port Menu 
4.3  Configuring IPmux-11 for Operation 
Configuring the System Clock 
You can configure the parameters of the IPmux-11 system clock, including the 
master clock and fall back clock. If the clock is adaptive or Rx clock then you can 
also configure the clock source. 
 
If the configured fallback clock source fails, the internal timing is used as the fallback 
clock source instead. 
 
 
To configure the system clock: 
1.  From the System menu (
), select System clock.  
The System clock menu appears (See 
 
2.  From the System clock menu, configure the following:  
 
Master clock (Master clock type): 
 
Internal 
 
Adaptive 
 
Rx clock 
 
Master source (Master clock source): 
 
Channel 1 
 
Channel 2 
 
Channel 3 
Note