Vermont Casting IRFSDV34 Manuel D’Utilisation

Page de 28
25
Irving Oil
10004000
 TROUBLE SHOOTING THE GAS CONTROL SYSTEM
Set manual switch
to local or remote
Light pilot burner
Five minute 
wait period
Did the LED stop 
       blinking?
No
Review LED
failure analysis
Release pilotstat
        knob
Turn pilotstat knob
from PILOT to ON
Cycle switch once and
leave in remote. Press any
key on transmitter for
recognition operation
Choose Manual or
Remote path. Set 
switch to manual or
         remote.
If manual switch is 
set to LOCAL, did
main buen light and 
      fan turn on?
      Move switch from
manual to remote. Press
any key on transmitter.
Move switch back to 
            manual.
Turn pilotstat knob
to PILOT to turn off
main burner.
Yes
Turn pilotstat knob
to OFF to turn valve
completely off.
Local Path
If the manual switch is
       set to remote, 
press the mode button
to display "ON". Does
transmitter control the 
main burner and fan?
Move switch from 
manual to remote. 
Press any key on 
transmitter.
Does transmitter
change levels of flame 
height, fan speed?
No
Yes
Yes
Set levels of flame
height and fan to "0" 
to shut off main burner 
and fan.
Turn pilotstat knob to
   OFF to turn valve 
     completely off.
On Path
Auto Path
If the manual switch is
       set to remote, 
press the mode button
  to display AUTO on 
the transmitter. Does the 
  transmitter display the 
 room and temperature
            setting?
Move switch from 
LOCAL to REMOTE.
Press any key within
30 seconds.
If the setting is
above room temperature
on the transmitter, does
the main valve and fan 
turn on?
If the setting is below
room temperature on the 
transmitter, does the
main valve and fan 
turn off?
 Turn pilotstat knob to
OFF to turn valve com-
        pletely off.
No
No
Comfort Valve system control sequence of operation with transmitter