Whirlpool 250 Manuel D’Utilisation

Page de 14
S E R V I C E
Whirlpool Europe
AWM 250/3
17.08.1998 / Page 3
Customer Service
8570 250 10010
Doc. No: 4812 712 13517
Technical data
Drain pump (synchronus)
Nominal voltage
230
V
Nominal current
0.3
A
Nominal consumption
34
W
Frequency
50
Hz
Resistor (coil)
155
Ω ±
 7%
Motor protection
no
Capacity (1.25m height)
15
l/min.
±
 2
Program timer
Type
Hybridtimer with integreated
electronic
Fab.
EC 4477
(Timer 2 a mask5)
Nominal voltage
230
V
Frequency
50
Hz
Total positions
60
Cotton/coloured laundry
Pre wash
pos.
01 - 02
Main wash
pos.
03 - 12
Rinse
pos.
13 - 19
Spin
pos.
20 - 22
Stop
pos.
23
Easy care
Pre wash
pos.
24 - 26
Main wash
pos.
27 - 34
Rinse
pos.
35 - 39
Spin
pos.
40 - 41
Stop
pos.
42
Delicate
Pre wash
pos.
43 - 44
Main wash
pos.
45 - 51
Rinse
pos.
52 - 56
Spin
pos.
57 - 59
Stop
pos.
60
Wool
Pre wash
pos.
 -
Main wash
pos.
47 - 51
Rinse
pos.
52 - 56
Spin
pos.
57 - 59
Stop
pos.
60
Silk
Pre wash
pos.
 -
Main wash
pos.
49 - 51
Rinse
pos.
52 - 56
Spin
pos.
57 - 59
Stop
pos.
60
Motor
Type
MCA 52/64 - 148 t.f./WHE0
i = 1 : 13.1
Resistance contacts
6 - 7
68.70
Ω ±
 7%
4 - 5
2.15
Ω ±
 7%
2 - 3
1.46
Ω ±
 7%
1 - 3
0.65
Ω ±
 7%
Radio interference supression
Type
Friburg FA 26
Nominal voltage
230
V
Nominal capacity
470nFX1+2x22nFY
Nominal inductances
2 x 1
mH
Nominal resistance
680
k
Ω
Selector switch
Positions
7
Nominal voltage
5
V
Value of resistors:
1-2-3
internal shunt
4-6
internal shunt
5-6
pos.1
0
Ω
pos.2
0.68 k
Ω±
 5%
pos.3
1.10 k
Ω±
 5%
pos.4
1.80 k
Ω±
 5%
pos.5
2.70 k
Ω±
 5%
pos.6
3.60 k
Ω±
 5%
pos.7
4.70 k
Ω±
 5%
Push botton switch
Start stop
SM
1/2 load
SHL
Eco
SEC
Pre wash
SPW
Rapid
SR