TROUBLESHOOTING
 WARNING: Turn off log set and let cool before servicing. Only a 
qualified service person should service and repair log set.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
REMEDY
OBSERVED PROBLEM
1..Poor.fuel.quality
..Fireplace.venting.system.
not.drafting.properly
3..Improper.fuel/air.mix
4..Excessive. gas. supply. or.
pressure.
1..Passage. of. air. or. gas.
across.irregular.surfaces
1..Incorrect. gas. supply. or.
pressure
2. Blocked  burner  orifice  or 
burner.manifold
3..Improper. burner. orifice.
size
Log. set. is. smoking/sooting.
excessively.
(Note:  It  is  natural  and  un-
avoidable for vented gas log 
sets  to  produce  moderate 
levels of carbon (soot) where 
flames contact logs.
.
Burner. is. excessively. noisy.
(Note:  The  movement  and 
combustion  of  gas  will  cre-
ate  low,  unavoidable  levels 
of noise.)
Burner  flame  is  too  low  or 
too.high
1..Contact.local.gas.supplier
2. Adjust  damper  wide  open 
and/or  have  fireplace  and 
venting. professionally.
cleaned.and.checked
3..Remove.any.foreign.items.
from  flame  pattern  and/or 
check. for. proper. orifice.
sizing
4. Preheat  flue  in  very  cold 
weather.
1..Relieve.any.tight.bends.or.
kinks.in.gas.supply.line
1..Check.for.proper.gas.sup-
ply.pressure
..Free. burner. orifice. and.
manifold ports of any burrs, 
paint.or.other.blockage
3..Verify. proper. burner. ori-
fice sizing (see Figure 2, 
page 6)