Honeywell IV REV B Manuel D’Utilisation

Page de 132
Fusion IV DVR User Guide 
 
________________________________________________________________________________________________________ 
Document 800-05305V1 Rev B 
127 
10/11 
 
Setting up the Server to Accept Incoming Communications 
In order to access the DVR remotely, the DVR Server must be setup to allow remote 
connections.  
 
 
Disable Remote 
Control 
Enables/Disables acceptance of remote connections by the DVR server. 
Time Out Value 
Specifies a value (in seconds) to wait for a signal from the Fusion 
Remote Client. If a signal is not received by that time, the connection is 
dropped. 
Center Port 
Used by the DVR to transfer the connection data. 
Image Port 
Used by the DVR to transfer the image data. 
Search Port 
Used by the DVR to transfer the search data 
 
1.  Enter Setup on the DVR. 
2.  Click the Network tab. 
3.  Clear the Disable Remote Control check box.  
Note
 
If a Firewall is used, it may be necessary to adjust the port settings on both 
the DVR and the Firewall. Contact the Network Administrator for more 
information. 
4.  Click OK. 
5.  Make sure a User account is created.  Without a user account, the Administrator 
account must be used. 
6.  The DVR server is now ready to receive incoming connections.