Honeywell HSVR-04 Manuel D’Utilisation

Page de 161
Honeywell 
 
37 
Motion Detection 
The detection menu is shown as below. See 
  Event type: From the drop-down list you can select the “Motion 
Detection” type. 
  Channel: Select the video channel for the motion detection setting. 
  Record Channel: Select the channel to activate the recording function 
once the alarm has  sounded. Please make sure you have set the MD 
recording in the schedule interface (Main MenuSettingSchedule
and automatic recording in manual record interface (Main Menu-
>Advanced->Manual Record)  
  Delay: When detected motion is completed, the system will continue 
alarm output and recording for a specified time respectively. The value 
ranges from 10-300(Unit: second). 
 Region: 
Click 
Select, the interface is shown as in 
. Here 
you can set the motion detection zone. There are 396(PAL)/330(NTSC) 
small zones. 
  Sensitivity: The system supports 6 levels. The sixth level has the 
highest sensitivity. The fifth or lower levels are recommended to avoid 
setting a false alarm. 
  Show message: The system will send message to the local host screen 
to alarm you if you have enabled this function. 
  Send email: The system can send out an email to alert you when the 
alarm occurs.  
  PTZ activation: Here you can set PTZ movement (of any video 
channels) such as going to a preset when motion is detected in the 
current video channel. Click Select, and you can see an interface is 
shown as in 
 Period: 
Click 
Set to determine the period for the channel to be armed 
for motion detection. See the interface shown as in 
you can set for business days and non-business days. In 
click Set, and you will see an interface as shown in 
you can set your own business day and non-business day. 
  Alarm output: After the motion detection has occurred, the system 
enables the peripheral alarm devices. 
  Tour: Here you can enable the tour function when the alarm occurs.  It 
is a one-window tour. Please go to 
setup.