There are the following possibilities: 
• 
Alarm setup is incorrect. 
• 
Alarm output has been opened manually. 
• 
Input device error or connection is incorrect. 
• 
Some program versions may have this problem. Please upgrade 
your system. 
 
19.  Alarm function is null. 
There are following possibilities: 
• 
Alarm setup is incorrect.  
• 
Alarm cable connection is incorrect. 
• 
Alarm input signal is incorrect. 
• 
There are two loops connected to one alarm device.  
 
20.  Remote control does not work.  
There are the following possibilities: 
• 
Remote control address is incorrect. 
• 
Distance is too far or control angle is too small. 
• 
Remote control battery power is low. 
• 
Remote control is damaged or DVR front panel is damaged. 
 
21.  Record storage period is insufficient.  
There are the following possibilities: 
• 
Camera quality is too low. Lens is dirty. Camera is installed against 
the light. Camera aperture setup is incorrect.  
• 
HDD capacity is not enough. 
• 
HDD is damaged.  
 
22.  Cannot playback the downloaded file. 
There are following possibilities: 
• 
There is no media player.