Approach Tech DVR-3024 Manuel D’Utilisation

Page de 71
 
8
ALARM1 IN
ALARM4 IN
ALARM2 IN
ALARM3 IN
ALARM OUT
RECORD IN
GROUND
DISK FULL
ALARM RESET
1
2
3
4
5
6
7
8
9
5V
0V(Active)
5V
0V(Active)
 
 
1.4 ALARM In / Out 
 
 
 
 
 
 
 
 
 
The above figure is the rear view.
 
1. GND: 
Ground Contact. 
2. ALARM 
OUT 
(OUTPUT): 
This is an 
alarm output trigger. Connect this to 
external devices such as buzzers or 
lights.   
5V
0V(Active)
 
3.  DISK FULL (OUTPUT): This is a disk full 
output trigger. Connect this to external 
devices such as buzzers or lights.   
5V
0V(Active)
 
4. ALARM RESET (INPUT): This pin 
connects to an alarm-clear device for 
clearing an alarm.   
5V
0V(Active)
 
5. 
RECORD IN (INPUT): This pin connects 
to a record trigger device for starting a 
record.   
 
6.  ALARM4 IN (INPUT): This is an alarm 
input (for CH 4), which can be 
programmed in the menu system to 
Normally Open or Normally Closed.   
 
 
7. 
ALARM3 IN (INPUT): same as the above, 
for CH 3 
8. 
ALARM2 IN (INPUT): same as the above, 
for CH 2 
9. 
ALARM1 IN (INPUT): same as the above, 
for CH 1