Avaya S8100 Manuel D’Utilisation
1
Install and cable a G600 cabinet
Complete installation
S8100 Installation and Upgrades
137
November 2003
Figure 46: Setting the neon voltage
1
Call a telephone with a neon message indicator and leave a message.
2
Check for ring ping (single ring pulse) each time the lamp flashes (approximately every 3
seconds).
seconds).
3
Adjust the control clockwise in small increments until the ring ping stops. Ensure that the
message lamp still lights when the adjustment is finished.
message lamp still lights when the adjustment is finished.
Complete installation
1
Disconnect the laptop.
2
Remove the RJ45 connector used to connect the laptop.
3
Insert the flash disk.
4
Set the left and right doors of the CMC1 onto the hinge pins and close the door(s). The doors must
be closed to prevent EMI emissions. Tighten the door screws.
be closed to prevent EMI emissions. Tighten the door screws.
5
For the CMC1, set the right cover panel onto the right panel and secure. Do not use force.
didmt1 KLC 053097