Manuel D’UtilisationTable des matièresTitle Page1Table of Contents3Introduction to the 3ware Command Line Interface8Features of the CLI8Supported Operating Systems9Terminology9Installing the 3ware CLI10Installing the 3ware CLI on Windows10Permissions Required to Run CLI10Installing the 3ware CLI on Linux and FreeBSD11Working with 3ware CLI12Using the command interface interactively12Using a single command with output13Using an input file to execute a script13Scripting example13Outputting the CLI to a Text File14Conventions14Understanding RAID Levels and Concepts15RAID Concepts15Available RAID Configurations16RAID 016RAID 117RAID 517RAID 618RAID 1019RAID 5020Single Disk21JBOD21Hot Spare22Determining What RAID Level to Use22Using Drive Capacity Efficiently23Support for Over 2 Terabytes24CLI Syntax Reference25Common Tasks Mapped to CLI Commands25Syntax Overview27Shell Object Commands29focus Object29show30show ver31show alarms [reverse]32show diag32show rebuild32show verify33show selftest33flush34rescan34commit34update fw=filename_with_path [force]34Controller Object Commands35/cx show36/cx show attribute [attribute ...]37/cx show driver38/cx show model38/cx show firmware38/cx show bios38/cx show monitor38/cx show serial39/cx show pcb39/cx show pchip39/cx show achip39/cx show numdrives39/cx show numports40/cx show numunits40/cx show ctlbus40/cx show exportjbod40/cx show spinup41/cx show stagger41/cx show ondegrade41/cx show autocarve41/cx show carvesize42/cx show memory42/cx show autorebuild43/cx show unitstatus43/cx show allunitstatus44/cx show drivestatus44/cx show all45/cx add type=<RaidType> disk=<p:-p> [stripe=Stripe] [noscan] [group=<3|4|5|6|7|8>] [nocache] [autoverify] [noqpolicy][ignoreECC] [name=string] [storsave=<protect|balance|perform>]46/cx rescan [noscan]49/cx commit50/cx flush50/cx update fw=filename_with_path [force]50/cx show alarms [reverse]51/cx show diag52/cx show rebuild52/cx show verify54/cx show selftest55/cx add rebuild=ddd:hh:duration56Setting Up a Rebuild Schedule56/cx add verify=ddd:hh:duration57Setting Up a Verify Schedule57/cx add selftest=ddd:hh58Setting Up a Selftest Schedule58/cx del rebuild=slot_id59/cx del verify=slot_id59/cx del selftest=slot_id59/cx set rebuild=enable|disable|1..559/cx set verify=enable|disable|1..560/cx set selftest=enable|disable [task=UDMA|SMART]60/cx set exportjbod=on|off61/cx set ondegrade=cacheoff|follow61/cx set spinup=nn61/cx set stagger=nn62/cx set autocarve=on|off62/cx set carvesize=[1024..2048]62/cx set autorebuild=on|off63/cx set autodetect=on|off disk=<p:-p>|all63/cx start mediascan64/cx stop mediascan65Unit Object Commands65/cx/ux show66/cx/ux show attribute [attribute ...]67/cx/ux show status67/cx/ux show rebuildstatus67/cx/ux show verifystatus67/cx/ux show initializestatus68/cx/ux show name68/cx/ux show serial68/cx/ux show qpolicy68/cx/ux show storsave69/cx/ux show identify69/cx/ux show autoverify69/cx/ux show cache69/cx/ux show ignoreECC70/cx/ux show volumes70/cx/ux show all70/cx/ux remove [noscan] [quiet]71/cx/ux del [noscan] [quiet]72/cx/ux start rebuild disk=p<p:-p...> [ignoreECC]72/cx/ux start verify73/cx/ux pause rebuild73/cx/ux resume rebuild73/cx/ux stop verify74/cx/ux flush74/cx/ux set autoverify=on|off74/cx/ux set cache=on|off [quiet]74/cx/ux set identify=on|off75/cx/ux set ignoreECC=on|off75/cx/ux set name=string76/cx/ux set qpolicy=on|off76/cx/ux set storsave=protect|balance|perform [quiet]76/cx/ux migrate type=RaidType [disk=p:-p] [group=3|4|5|6|7|8] [stripe=Stripe] [noscan] [nocache] [autoverify]78Migration Process81Example of splitting a mirror81Example of capacity expansion81Example of migrate output82Port Object Commands83/cx/px show83/cx/px show attribute [attribute ...]83/cx/px show status84/cx/px show model84/cx/px show serial84/cx/px show firmware84/cx/px show identify84/cx/px show ncq85/cx/px show lspeed85/cx/px show capacity85/cx/px show smart85/cx/px show all86/cx/px remove [noscan] [quiet]87/cx/px set identify=on|off87BBU Object Commands88/cx/bbu show88/cx/bbu show attribute [attribute ...]89/cx/bbu show status89/cx/bbu show batinst90/cx/bbu show lasttest90/cx/bbu show volt90/cx/bbu show temp90/cx/bbu show cap90/cx/bbu show serial91/cx/bbu show fw91/cx/bbu show pcb91/cx/bbu show bootloader91/cx/bbu show all91/cx/bbu test [quiet]92/cx/bbu enable92/cx/bbu disable [quiet]92Enclosure Object Commands93/ex show93/ex show attribute [attribute ...]94/ex show controllers94/ex show slots95/ex show fans95/ex show temp95/ex show all95/ex/slotx show96/ex/slotx show identify96/ex/slotx set identify=on|off96/ex/fanx show97/ex/tempx show97Help Commands97Help with specific commands97Help with attributes99help99help show100help flush100help rescan100help update100help commit100help focus101help /cx101help /cx/ux101help /cx/px101help /cx/bbu101help /ex101help /ex/slotx101help /ex/fanx102help /ex/tempx102Command Logging102Return Code102Taille: 530 koPages: 103Language: EnglishOuvrir le manuel