Manuel D’UtilisationTable des matièresChapter 1 System Description11.1 Abbreviation11.2 Introduction11.3 Features11.4 System Configuration21.5 Components41.5.1 Rectifier Shelf41.5.2 Rectifier61.5.3 SCU71.5.4 Multi-Function Unit (MFU)91.5.5 Battery Connection Unit (BCU)101.5.6 System Cabinet11Chapter 2 Installation122.1 Installation Preparation122.1.1 Environmental Conditions122.1.2 Power Supply122.1.3 Site Survey132.1.4 Tools & Material132.1.5 Unpacking142.2 Installation Procedures152.2.1 Cabinet Installation152.3 External Electrical Connection Interface172.3.1 Connection Of Input Cables172.3.2 Connection Of Load Cables202.3.3 Connection Of Communication Cables212.3.4 Layout Of Connector Board S6415X2222.3.5 Interface Definition Of Connector Board S6415X2232.3.6 Connection Of Temperature Sensor Cables242.3.7 Connection With MODEM242.3.8 Connection With Dry Contacts252.4 Battery Installation And Cabling252.4.1 Battery Installation252.4.2 Battery Cable Connection262.5 Parallel Connection Of Cabinets29Chapter 3 Startup303.1 Checking Before Startup303.2 Startup Process313.3 Parameters Configuration31Chapter 4 Testing324.1 Testing MFU324.2 Testing Rectifier324.3 Testing SCU324.4 Battery Breaker Test334.5 BCU Test334.6 Load Breaker Test33Chapter 5 Operating SCU345.1 Operation Panel345.2 Operation Procedures355.3 Querying System Status365.3.1 First Page Of System Information365.3.2 Other System Information Screen375.4 Querying Rectifier Status395.5 Querying Alarms And Setting Alarm Plans405.5.1 Querying Active Alarm405.5.2 Query Alarm History415.5.3 Alarm Type Table435.5.4 Changing Audible/Visual Alarm And Alarm Call Back Plan465.5.5 Changing Alarm Types Of Dry Contacts465.5.6 Setting Alarm Type For Dry Contacts465.5.7 Set the Alarm Names Through PLC Function485.6 Maintenance515.7 Setting System Parameters535.7.1 Parameter Setting Method535.7.2 Batt. Selection555.7.3 LVD Parameter Description565.7.4 Charging Management Parameters575.7.5 Battery Test Parameters605.7.6 Temperature Compensation Coefficient Parameters625.7.7 AC Settings635.7.8 DC Setting645.7.9 Rect Settings655.7.10 System Settings665.7.11 Alarm Settings70Chapter 6 Routine Maintenance726.1 Maintenance Of Rectifier726.2 Maintenance Of SCU726.3 Maintenance Of MFU726.4 Cover Plates736.5 Battery Maintenance736.5.1 Storage And Supplementary73Daily Inspection73Replacement74Chapter 7 Troubleshooting757.1 Troubleshooting Rectifier757.2 Mains Failure767.3 Disastrous Accidents76System Technical Parameters77Engineering Design Diagram79Appendix 2.4 System Input And Output Connector Specs81Appendix 3 System Circuit Diagram82Appendix 3.1 System Electric Schematic Diagram82Appendix 3.2 System Wiring Diagram83Appendix 3.3 MFU Electric Wiring Diagram84Appendix 3.4 BCU Electric Wiring Diagram85Glossary86Configurations of Actura Flex 48330 Power System3Dimensions of rectifier shelf5Function of indicators7Authority and default password9Configuration of MFU10BCU configuration11Environmental conditions in power room12AC input modes17Configuration number of load MCBs and battery MCBs20Interface definition of connector board S6415X223System checklist before startup30Functions of LED indicators34Functions of SCU keys34Alarm type table43Changing audible/visual alarm and alarm call back plan46Optional alarm types47Logic matrix used for configuring 8 dry contacts49Example of PLC setting49PLC SN and Alarm49Password levels and authorities54Value description of the basic battery parameters56Value description of the LVD parameters57Charging management parameter value description59Value description of the battery test parameters61Value description of temperature compensation coefficient62Value description of AC settings63Value description of DC settings64Value description of rectifier settings65Value description of system settings68Relationship between system model and system type70Value description of alarm settings71Troubleshooting75Outline2Rectifier shelf outline4Rectifier shelf with rectifiers and CU4Dimensions6Outline of SCU7Outline and components of MFU9Outline of battery connection unit (BCU)10Installation dimensions of the cabinet base15Installing expansive pipe16Fixing cabinet with Tap16Cable mounted with H terminal17Connection of input terminals18Top cover18Connection of 3-phase AC power input18Connection of single-phase AC power input19Connection of dual-phase AC power input19Connection of load cables20Cable connection to MCB20Connector board in rectifier shelf21Layout of connector board S6415X222Input/output interfaces of TD-5648DC MODEM24Cabinet with four battery strings installed26Connection of battery cables.27Positive and negative battery cables in each level27Negative battery cables connection in BCU28Parallel connection of DC power system cabinet with battery cabinet29SCU Front Panel34BC/FC switchover diagram59Schematic diagram of the test function61System model description69Taille: 1,9 MoPages: 96Language: EnglishOuvrir le manuel