CDMA Measurements - Screens and Control Fields
Control Fields for CDMA Measurements
Time Offset
This field allows you to manually enter a time offset. To obtain a value 
to enter in this field you must make at least one of the following 
measurements.
• Power
• Timing
• Phase
• Rho
After making the measurement, access the 
FP Setup
 menu on the 
CODE DOM screen, and enter the value obtained from the 
Time Ofs 
field or, for rho measurements, the 
Time Offset
 measurement field on 
the CDMA ANALYZER screen.
An entry into the 
Time Offset
 field can also be made automatically, 
using the 
Ofs Trnsfer
 field. See 
.
When measuring fast power, the code domain analyzer uses the value 
in the 
Time Offset
 field instead of re-measuring the time offset 
parameters each time a code domain measurement is made.
Screens on which this field is present
CODE DOM (Code Domain Analyzer, IS-95 only): FP setup controls 
menu
Time Ofs
This measurement field displays the time offset when a rho 
measurement is made. See 
 for more 
information about this measurement.
Screens on which this field is present
CODE DOM (Code Domain Analyzer).