Chapter 8
C:\Spk\Ref\RefGuideRevE\Enc-dec.fm
Signaling Encoder and Decoder - Screens and Control Fields
Control Fields for the Signaling Encoder and Decoder
On Time
For the encoder, this field sets the length of time each DTMF tone is on 
during the sequence. 
For the decoder, this measurement column lists the length of time each 
tone is on during the sequence. 
Screens Where Field is Present
SIGNALING ENCODER (Modes: DTMF)
SIGNALING DECODER (Modes: DTMF)
Polarity
This field is used to match the polarity of the encoded signal being 
analyzed.
This function is helpful to restore the proper data polarity when the 
transmitter, repeater, or receiver used in your communications system 
has an odd number of inversions; causing the received data to be 
inverted when decoded. (This is common when a signal is translated to 
a lower frequency using an LO whose frequency is higher than the 
signal’s frequency; or when inverting amplifiers are used.) 
Normal Operation
When this field is set to 
Norm
, a logical high (1) is displayed when a 
positive peak in the received signal is detected. A negative peak 
displays a logical low (0). 
Inverted Operation
 When this field is set to 
Invert
, a logical low (0) is displayed when a 
positive peak in the received signal is detected. A negative peak 
displays a logical high (1). 
Operating Considerations
Inverting amplifiers used in transmitters, receivers, and repeaters can 
cause an inversion of the modulating digital data. If the decoded signal 
does not display the expected results, change this field’s setting to see if 
the signal may be getting inverted before being decoded. 
Screens Where Field is Present
SIGNALING DECODER (Modes: AMPS-TACS, NAMP-NTAC)
SIGNALING ENCODER (Modes: AMPS-TACS, NAMP-NTAC)