Agilent Technologies E6380-90073 Manuale Utente

Pagina di 352
Chapter 1
105
GPIB Command Dictionary
CANalyzer subsystem
:MODE <string>
:MODE?
These commands set/query the measurement displayed in the upper 
left corner of the display.
Syntax
CAN:MODE ‘Avg Pwr’
‘ACP’
 ‘Rho’
 ‘EVM’
 ‘Chan 
Pwr’
CAN:MODE?
Screen/field equivalent
CAN:MODE selects the measurement to be displayed in the upper-left 
corner of the screen.