Agilent Technologies E6380-90073 Manuale Utente

Pagina di 352
114
Chapter 1
 
GPIB Command Dictionary
CBUFfer subsystem
CBUFfer subsystem
CBUF controls the CDMA data buffer. This system allows you to send 
CDMA data through the CDMA generator. You can send all zeroes, 
external data via the DATA IN connector, random data, or data 
supplied via GPIB.
:DATA <48 or 72 character hex string>
:DATA?
These commands set/query the actual data string sent in the CDMA 
data buffer. The command CGEN:DATA:SOUR ‘Data Buff ’ in the 
“CGENerator subsystem” on page 146 selects the data buffer as the 
data source.
Syntax
CBUF:DATA <hex string> !48 or 72 character hex string
CBUF:DATA?
Screen/field equivalent
CBUF:DATA is controlled by the 
Data Source
 field of the CDMA 
GENERATOR screen, but :DATA has no direct screen equivalent.
:FRAMe:COUNt <integer> <real number>
:FRAMe:COUNt?
These commands set/query the number of frames to be transmitted. It 
is applicable no matter what the source of data is (data buffer, zeroes, 
external, or random). This command utilizes the “Multiple Real 
Number Setting Syntax” on page  282, 
but does not use the :DUNits 
and :UNITs commands.
Syntax
CBUF:FRAM:COUN <integer>,<real 
number> 
CBUF:FRAM:COUN? <integer> !returns the count corresponding to 
‘integer’
Screen/field equivalent
CBUF:FRAM:COUN controls the 
# of Frames
 field of the CDMA 
GENERATOR screen. The 
# of Frame
 field is displayed when the 
Data 
Source
 is set to 
Data Buff
.