Agilent Technologies E6380-90073 Manuale Utente
Chapter 1
217
GPIB Command Dictionary
MEASure subsystem
:AFRequency:SNR <meas cmnd>
:AFRequency:SNR?
:AFRequency:SNR?
These commands set/query the SNR measurement. SNR must first be
selected using the MEAS:AFR:SEL ‘SNR’ command (see page 216).
selected using the MEAS:AFR:SEL ‘SNR’ command (see page 216).
Syntax
MEAS:AFR:SNR <meas cmd> !controls the SNR command
MEAS:AFR:SNR?
!returns the measurement’s value
Example
MEAS:AFR:SNR
!displays the measurement
Screen/field equivalent
MEAS:AFR:SNR? reads to the
SNR
measurement field on the AF
ANALYZER screen. This measurement is also displayed on the RF
GENERATOR and RF ANALYZER screens.
GENERATOR and RF ANALYZER screens.
:CANalyzer:ADC:APOWeradc:LEVel <meas cmnd>
:CANalyzer:ADC:APOWeradc:LEVel?
:CANalyzer:ADC:APOWeradc:LEVel?
These commands set/query the ADC for the average power
measurement. The ADC is a measure of how close the actual input
signal is to the maximum input level.
measurement. The ADC is a measure of how close the actual input
signal is to the maximum input level.
This measurement utilizes the Number Measurement Syntax, but does
not use the :METer command.
not use the :METer command.
Syntax
MEAS:CAN:ADC:APOW:LEV <meas cmd>
MEAS:CAN:ADC:APOW:LEV?
Example
MEAS:CAN:ADC:APOW:LEV? !displays the measured value
Screen/field equivalent
MEAS:CAN:ADC:APOW:LEV? reads the
ADC FS
measurement field on
the CDMA ANALYZER screen when an average power measurement is
selected. This measurement is also displayed on the CDMA
GENERATOR screen.
selected. This measurement is also displayed on the CDMA
GENERATOR screen.