Agilent Technologies E6380-90073 Manuale Utente

Pagina di 352
220
Chapter 1
 
GPIB Command Dictionary
MEASure subsystem
:CANalyzer:ERRor:FREQuency <meas cmnd>
:CANalyzer:ERRor:FREQuency?
These commands set/query the frequency error measurement. 
This measurement utilizes the Number Measurement Syntax, but does 
not use the :METer command.
Syntax
MEAS:CAN:ERR:FREQ <meas cmd> 
MEAS:CAN:ERR:FREQ?
Example
MEAS:CAN:ERR:FREQ? 
Screen/field equivalent
MEAS:CAN:ERR:FREQ? reads the 
Frequency Error
 measurement 
field on the CDMA ANALYZER screen. This measurement is also 
displayed on the CDMA GENERATOR screen.
:CANalyzer:ERRor:MAGNitude <meas cmnd>
:CANalyzer:ERRor:MAGNitude?
These commands set/query the magnitude error measurement. 
This measurement utilizes the Number Measurement Syntax, but does 
not use the :METer command.
Syntax
MEAS:CAN:ERR:MAGN <meas cmd> 
MEAS:CAN:ERR:MAGN?
Example
MEAS:CAN:ERR:MAGN? 
Screen/field equivalent
MEAS:CAN:ERR:MAGN? reads the 
Magnitude Error
 measurement 
field on the CDMA ANALYZER screen. This measurement is also 
displayed on the CDMA GENERATOR screen.