Agilent Technologies E6380-90073 Manuale Utente

Pagina di 352
Chapter 1
255
GPIB Command Dictionary
MEASure subsystem
:CDANalyzer:IS2000:TRACe:POWer:COMPlex:I[:VALue]?
:CDANalyzer:IS2000:TRACe:POWer:COMPlex:COMBined[:VALue]?
IS-2000 only. This query returns an array of 128 values that represents 
the Spreader I Input Power of both IS-95 and IS-2000 channels relative 
to the selected reference power value.
NOTE
The values returned represent the absolute power of individual Walsh 
channels not the supplemental channels of which they may be a part. 
The power of supplemental channels must be read directly from 
I Pwr Level
 fields on the CODE DOMAIN screen when Complex 
Power measurement has been selected.
Syntax
MEAS:CDAN:IS2000:TRAC:POW:COMP:I[:VAL]?
MEAS:CDAN:IS2000:TRAC:POW:COMP:COMB[:VAL]?
Screen/field equivalent
MEAS:CDAN:IS2000:TRAC:POW:COMP:I[:VAL]? and 
MEAS:CDAN:IS2000:TRAC:POW:COMP:COMB[:VAL]? returns 
information (top set of bars) displayed for the Complex Power 
measurement when 
CD pwr unit 
is set to 
Rel 
on the 
Reference 
menu on the CODE DOMAIN screen when the CDMA standard is set to 
“IS-2000”.