GPIB Command Dictionary
AFG2|ENCoder subsystem
:AMPS|TACS:MESSage:DATA1 <string>
:AMPS|TACS:MESSage:DATA2 <string>
:AMPS|TACS:MESSage:DATA1?
:AMPS|TACS:MESSage:DATA2?
:AMPS|TACS:MESSage:DATA2 <string>
:AMPS|TACS:MESSage:DATA1?
:AMPS|TACS:MESSage:DATA2?
These commands set/query FOCC Stream A and Stream B message
data. Like the filler data, the message information can only be input in
full (seven digit) lines. Also, message streams A and B must have the
same number of lines in them.
data. Like the filler data, the message information can only be input in
full (seven digit) lines. Also, message streams A and B must have the
same number of lines in them.
To use this command, AFG2:AMPS:CHAN must be set to ‘Cntl’.
Syntax
AFG2:AMPS:MESS:DATA1 <string>
AFG2:AMPS:MESS:DATA2 <string>
AFG2:AMPS:MESS:DATA1?
AFG2:AMPS:MESS:DATA2?
Screen/field equivalent
AFG2:AMPS:MESS controls the
Message
fields for FOCC Stream A
and Stream B on the SIGNALING ENCODER screen when the
Mode
field is set to
AMPS-TACS
. These fields are displayed only when the
Channel
field is set to
Cntl
.
:AMPS|TACS:SAT:AM <real number>
:AMPS|TACS:SAT:AM?
:AMPS|TACS:SAT:AM?
These commands set/query the SAT level when the AFG2:DEST ‘AM’
and AFG2:AMPS:CHAN ‘Voice’ commands are used. The SAT level
units are %.
and AFG2:AMPS:CHAN ‘Voice’ commands are used. The SAT level
units are %.
This command utilizes the “Real Number Setting Syntax” on page 299.
Syntax
AFG2:AMPS:SAT:AM
AFG2:AMPS:SAT:AM?
Screen/field equivalent
AFG2:AMPS:SAT:AM controls the
SAT Level
field when
AFGen2 To
field is set to
AM
on the SIGNALING ENCODER screen when the
Mode
field is set to
AMPS-TACS
and the
Channel
field is set to
Voice
.