GPIB Command Dictionary
AFG2|ENCoder subsystem
:AMPS|TACS:MESSage:DATA1 <string>
:AMPS|TACS:MESSage:DATA2 <string>
:AMPS|TACS:MESSage:DATA1?
:AMPS|TACS:MESSage:DATA2?
These commands set/query FOCC Stream A and Stream B message 
data. Like the filler data, the message information can only be input in 
full (seven digit) lines. Also, message streams A and B must have the 
same number of lines in them. 
To use this command, AFG2:AMPS:CHAN must be set to ‘Cntl’.
Syntax
AFG2:AMPS:MESS:DATA1 <string>
AFG2:AMPS:MESS:DATA2 <string>
AFG2:AMPS:MESS:DATA1?
AFG2:AMPS:MESS:DATA2?
Screen/field equivalent
AFG2:AMPS:MESS controls the 
Message
 fields for FOCC Stream A 
and Stream B on the SIGNALING ENCODER screen when the 
Mode
 
field is set to 
AMPS-TACS
. These fields are displayed only when the 
Channel
 field is set to 
Cntl
.
:AMPS|TACS:SAT:AM <real number>
:AMPS|TACS:SAT:AM?
These commands set/query the SAT level when the AFG2:DEST ‘AM’ 
and AFG2:AMPS:CHAN ‘Voice’ commands are used. The SAT level 
units are %. 
Syntax
AFG2:AMPS:SAT:AM 
AFG2:AMPS:SAT:AM?
Screen/field equivalent
AFG2:AMPS:SAT:AM controls the 
SAT Level
 field when 
AFGen2 To
 
field is set to 
AM
 on the SIGNALING ENCODER screen when the 
Mode
 
field is set to 
AMPS-TACS
 and the 
Channel
 field is set to 
Voice
.