Gas Requirements
IMPORTANT: Any product revisions or conversions 
must be made by the Manufacturer’s Authorized 
Dealers, Distributors or local service personnel.
IMPORTANT: The installation must comply with 
local codes or, in the absence of local codes:
 with the latest edition of the “National Fuel 
Gas Code,” ANSI Z223.1/NFPA 54 in the 
U.S.A.
 with CAN/CSA-B149.1 Natural Gas and 
Propane Installation Code in Canada
 and Gas Installations Standard AS/NZS 5601 
Part 1: General Installations in Australia and 
New Zealand
Obtain specific gas service pipe size from the gas 
supplier. Refer to Table 7 for general pipe size.
The following must be furnished and installed by the 
customer for the gas service line to each tumble dryer. 
Refer to Figure 10.
 Sediment traps
 Shut-off valves
 Supply pressure taps
It is important that equal pressure be maintained at all 
tumble dryer gas connections. This can be done by 
installing a one inch (25 mm) pipe gas loop. Refer to 
NATURAL GAS recommended line pressure is 6.5 
water column inches (1.62 kPa), with no less than 5 
water column inches (1.24 kPa) and no more than 10.5 
water column inches (2.61 kPa), with all gas 
appliances running (tumble dryers, water heaters, 
space heaters, furnace, etc.). An in-line pressure 
regulator may be required if the line pressure exceeds 
10.5 water column inches (2.61 kPa) with all gas 
appliances running. 
LIQUID PETROLEUM GAS (L.P.) line pressure must 
be maintained at 11 water column inches (2.74 kPa), 
with no less than 10 water column inches (2.49 kPa) 
and no more than 13 water column inches (3.23kPa), 
with all gas appliances running (tumble dryers, water 
heaters, space heaters, furnace, etc.).
For converting Non-CE Models from Natural Gas to 
L.P. Gas:
120 Pound Models - M4973P3
170 Pound Models - M4974P3
CE GASES refers to Installing CE Gas Drying 
Tumble Dryers section, the above data does not apply 
to the CE. 
WARNING
To reduce the risk of fire or explosion, DO 
NOT CONNECT THE GAS LINE TO THE 
TUMBLE DRYER IF THE GAS SERVICE IS 
NOT THE SAME AS THAT SPECIFIED ON 
THE TUMBLE DRYER SERIAL PLATE! It 
will first be necessary to convert the gas 
burner orifice and gas valve. Appropriate 
conversion kits are available.
W060R1
WARNING
The tumbler and its individual shut-off 
valve must be disconnected from the gas 
supply piping system during any 
pressure testing of that system at test 
pressures in excess of 0.5 psig (3.45 kPa).
The tumbler must be isolated from the 
gas supply piping system by closing its 
individual manual shut-off valve during 
any pressure testing of the gas supply 
piping system at test pressure equal to or 
less than 0.5 psig (3.45 kPa).
W061R2
WARNING
To reduce the risk of fire or explosion, if 
the tumble dryer is to be connected to 
Liquefied Petroleum (L.P.) gas, a vent to 
the outdoors must be provided in the 
room where the tumble dryer is installed.
W062R1