Electrical Requirements
NOTE: To ensure protection against shock, this 
tumble dryer MUST be electrically grounded in 
accordance with the local codes or, in the absence of 
local codes, with the latest edition of the National 
Electrical Code ANSI/NFPA No. 70. In Canada the 
electrical connections are to be made in accordance 
with CSA C22.1 latest edition Canadian Electrical 
Code, Part I and/or local codes. Electrical work 
should be done by a qualified electrician.
IMPORTANT: Electrical connections must be 
made by a qualified electrician using data on serial 
plate, installation manuals and wiring diagram 
provided with machine and according to local 
codes. Install a circuit breaker as close to the 
tumble dryer as possible. If more than one tumble 
dryer is being installed, a circuit breaker must be 
provided for each.
NOTE: Connect machine to an individual branch 
circuit not shared with lighting or other equipment.
NOTE: 3 Phase Machines Only - Do not use fuses 
to avoid the possibility of “single phasing” and 
causing premature failure of the motors.
Grounding Instructions
This tumble dryer must be grounded. In the event of 
malfunction or breakdown, grounding will reduce the 
risk of electric shock by providing a path of least 
resistance for electric current. This tumble dryer must 
be connected to a grounded metal, permanent wiring 
system; or an equipment grounding conductor must be 
run with the circuit conductors and connected to the 
appropriate ground location.
Metal conduit and/or BX cable is not considered 
ground. Connecting the Neutral from the electrical 
service box to the tumble dryer ground screw does not 
constitute a ground. A dedicated ground conduit (wire) 
must be connected between the electrical service box 
ground bar and the tumble dryer ground screw.
To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the tumble 
dryer before servicing.
• Close gas shut-off valve to gas tumble 
dryer before servicing.
• Close steam valve to steam tumble dryer 
before servicing.
• Never start the tumble dryer with any 
guards/panels removed.
• Whenever ground wires are removed 
during servicing, these ground wires 
must be reconnected to ensure that the 
tumble dryer is properly grounded.
W002R1
To reduce the risk of fire and electric 
shock, check with a qualified serviceman 
for proper grounding procedures. 
Improper connection of the equipment 
grounding conductor may result in a risk 
of electric shock.
W068
To reduce the risk of fire and electric 
shock, if electrical supply is coming from a 
three phase service, DO NOT connect a 
“High Leg” or “Stinger Leg” to a single 
phase machine. On a three phase machine, 
if there is a “High Leg” or “Stinger Leg” it 
should be connected to L3.
W069
WARNING
WARNING
In case of servicing (or putting the tumble 
dryer out of order), disconnect the tumble 
dryer from the main supply by switching 
off the circuit breaker.
W796