Alliance Laundry Systems 907003062 Manuale Utente

Pagina di 52
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Steam Requirements
45
70420801 (EN)
120 Pound Tumble Dryers
Figure 14 
TMB2014N
NOTE: Refer to Table 10 for sizing of steam lines. Piping must also be sized accordingly for length of runs and 
number of elbows. 
1
Supply
8
18 in. (457 mm) Drop
2
12 in. (305 mm) Riser
9
Solenoid Valve (Supplied with machine)
3
Shut-Off Valve
10
Steam Bonnet
4
Condensate Return Line from Supply Line
11
Flexible Line
5
Return
12
Union
6
Check Valve
13
Trap with Built-In Strainer
7
Vacuum Breaker (Optional)
TMB2014N
2
12
6
3
5
1
13
10
9
8
7
4
11
6
Model
Steam Pressure 
PSI (bar)
Minimum 
Supply Pipe Diameter
Steam Trap Size *
(Pounds Condensate/Hour)
120S 
80-100 (5.3-6.9)
1 in. NPT
345
*Based on maximum psi.
Table 10