Vermont Casting SDDVREB Manuale Utente

Pagina di 52
3
Stardance Direct Vent - Rear Vent Gas Heaters 
20012950
The Stardance Direct Vent Room Heater, Models. SDDVR Series: 
SDDVRCB, SDDVREB, SDDVRMB, SDDVRBS, SDDVRCH, SD-
DVRVG, SDDVRBD; SDDVRC Series: SDDVRCCB, SDDVRCEB, 
SDDVRCMB, SDDVRCBS, SDDVRCCH, SDDVRCVG, SDDVR-
CBD are vented gas appliances listed to ANSI Standard Z21.88-
2005  and CSA-2.33-2005 for Vented Room Heaters, and  CSA 
2.17-M91, Gas-Fired Appliances For Use at High Altitudes.
The installation of the Stardance Direct Vent Room Heaters must 
conform with local codes, or in the absence of local codes, with 
National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition 
and CSA B-149.1 (EXCEPTION:  Do not derate this appliance for 
altitude.  Maintain the manifold pressure at 3.5” w.c. for Natural 
Gas and 10” w.c. for LP gas at maximum input.) Refer to Page 
7 (RF only). 
This appliance is only for use with the type of gas indicated on the 
rating plate. This appliance is not convertible for use with other 
gases unless a certified kit is used. 
Installation  and  replacement  of  gas  piping,  gas  utilization 
equipment or accessories, and repair and servicing of equip-
ment shall be performed only by a qualified agency, preferably 
NFI or WETT (Canada) certified.  The term “qualified agency” 
means  any  individual,  firm,  corporation,  or  company  that 
either in person or through a representative is engaged in 
and is responsible for  (a) installation or replacement of gas 
piping, or (b), the connection, installation, repair, or servic-
ing of equipment, who is experienced in such work, familiar 
with all precautions required, and has complied with all the 
requirements of the authority having jurisdiction.
The Stardance Direct Vent Room Heaters should be inspected 
before use and at least annually by a qualified service agency. 
It is imperative that control compartments, burners, and cir-
culating air passageways of the appliance be kept clean. 
The Stardance Direct Vent Room Heaters and the individual shut-
off valve must be disconnected from the gas supply piping during 
any pressure testing of that system at test pressures in excess 
of 1/2 psig (3.5 kPa).
The Stardance Direct Vent Room Heaters must be isolated from 
the  gas  supply  piping  system  by  closing  the  individual  manual 
shutoff valve during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/2 psig.
An accessible tap is located above the pilot/on-off knob for check-
ing the inlet pressure.
‘Direct Vent’ describes a sealed combustion system in which in-
coming outside air for combustion and outgoing exhaust enter and 
exit through two separate concentric passages within the same 
sealed vent system. The system does not use room air to support 
combustion. The Direct Vent system permits the gas appliance to 
be vented directly to the outside atmosphere through the side of 
the house or vertically through the roof. 
This appliance is approved for bedroom installations in the U.S. 
and Canada.
This appliance may be installed in an aftermarket* manufactured 
(mobile) home, where not prohibited by state or local codes. 
WARNING: Operation of this heater when not connected to a 
properly installed and maintained venting system can result 
in carbon monoxide (CO) poisoning and possible death.
The Stardance Direct Vent Room Heater, when installed, must 
be electrically grounded in accordance with local codes or, in the 
absence of local codes, with the National Electrical Code ANSI/
NFPA  70,  (latest  edition),  or  of  the  current  Canadian  Electrical 
Code C22.1.
Due to high temperatures this appliance should be located 
out of traffic and away from furniture and draperies.
WARNING:  This appliance is hot while in operation.  Keep 
children, clothing, and furniture away.  Contact may cause 
burns or ignition of combustible materials.
Children and adults should be alerted to the hazards of high 
surface temperatures and should stay away to avoid burns or 
clothing ignition. Young children should be carefully super-
vised when they are in the same room as the appliance.
Clothing or other flammable materials should not be placed 
on or near the appliance. 
Any safety screen, glass or guard removed for servicing an ap-
pliance must be replaced prior to operating the appliance.
The appliance area must be kept clear and free from com-
bustible  materials,  gasoline,  and  other  flammable  vapors 
and liquids.
The flow of combustion and ventilation air must not be ob-
structed. The installation must include adequate accessibility 
and clearance for servicing and proper operation.
WARNING:  Do not operate the Room Heater with the glass 
panel removed, cracked or broken. Replacement of the panel 
should be done by a licensed or qualified service person.
Do not use this appliance if any part has been under water. 
Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system and 
any gas control which has been under water.
Do not burn wood, trash or any other material for which this 
appliance was not designed. This appliance is designed to 
burn either natural gas or propane only.
This gas appliance must not be connected to a chimney flue 
serving a separate solid-fuel burning appliance.
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and danger-
ous operation.
Verify proper operation after servicing.
* Aftermarket:
   Completion of sale, nor for purpose of resale, 
from the manufacturer.
Installation & Operating Instructions
Proposition 65 Warning: Fuels used in gas, woodburning or 
oil fired appliances, and the products of combustion of such 
fuels, contain chemicals known to the State of California to 
cause cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6
Stardance Direct Vent / Rear Vent
Certified to:
ANSI Z21.88-2005 / CSA Z2.33-2005 
Vented Gas Fireplace Heaters