Monte Carlo Fan Company 5CMR56 Manuale Utente

Pagina di 5
Install up light reflector to fan body.
Align hole in downrod with hole in
yoke and install cross pin.  
Install cotter pin into cross pin.
13
14
9
Take out pin and keeper clip and
then loosen the 2 set screws on the
yoke to let the downrod slip into
yoke.
12
Thead leadwires and safety cable
through the downrod.
11
Tighten the 2 set screws on the yoke
once the downrod is in place. Then
tighten locking nut.
15
For Canadian installation in both flush and downrod
mode the safety cable must be installed into the
house structure beams using the 3” lag screws pro-
vided.  Make sure that when the safety cable is
fully extended the leadwires are longer than the
cable and no stress is placed on the leadwires.
17
Canadian mounting only
Canadian mounting only
Safety Cable
Lag Screw
Install 4 Max. 15 watt bulbs into the
sockets on top of the fan as shown.
8
Install 4 screws to hold glass to fan
housing. Do not overtighten as this
could crack the glass.
7
Hang assembled fan from the mounting brack-
et. Make sure the fan is hanging straight.
Rotate fan until the tab on the Mounting brack-
et engages the slot on the Downrod Ball.  This
must be done to prevent the fan body from
rotating when the blades are in motion.
Rotating the ball will also close mount ring.
16
Install 4 screws to hold reflector in
place.
10
Make wire connections to power source using
wire nuts provided.  Make sure that no filiments
are outside of the wirenut. After making the
wire connections, the wires should be spread
apart with the grounded conductor and the
equipment-grounding conductor on one side of
the outlet box and ungrounded conductor on
the other side of the outlet box.
18