Avalon Stoves 21 DV Fireplace Manuale Utente

Pagina di 50
22
Installation  (for qualified installers only)
© Travis Industries
4040830
100-01143
Facing  Requirements
NOTE: The  combustible  area  above  the  facing  must  not  protrude  more  than  3/4"  from  the  facing.    If  it
does,  it  is  considered  a  mantel  and  must  meet  the  mantel  requirements  listed  in  this  manual.
Face Dimensions
Face
Height
Width
Bottom of Face
Installation Notes
Arched  Faces
35-1/2”
21-1/8”
Flush  w  base  of  fireplace
Arched  top  is  25-3/4”  radius
Bungalow,  T.  of  L.
35-3/
8”
21-1/8”
Flush  w  base  of  fireplace
Vict.  Lace
35-1/2”
21-1/8”
Flush  w  base  of  fireplace
Looking Glass
36-3/4”
23-1/2”
1-1/4” BELOW base of fireplace
Cast face is approx. 2” thick
Wilmington
36-3/4”
22-1/8”
1-1/4” BELOW base of fireplace
Facing Under 1” Thick
The facing (combustible 
or non-combustible) 
must maintain a 1/2” 
clearance to the sides 
and top of the fireplace.
Any material that protrudes 
more than 3/4” in front of the 
facing is considered a mantel 
and must meet the mantel 
requirements in this manual. 
4-3/4”
30-1/4”
(approx.)
3-3/8”
NOTE:  The facing tucks 
behind the flanges.
NOTE  The facing tucks under the notch at the front 
of the fireplace (3/8” above the base of the fireplace). 
a
b
c
Recommended Order of Installation We 
recommend installing the facing (drywall, tile) 
under the notch at the front of the fireplace 
(“a”) - then install the sides and top (“b” and 
“c”)
Facing Over 1” Thick
 
Facing  that  protrudes  in  front  of  the  face  above  the  face  (or  within  1/2”  of  each  side)  must  be
made  of  non-combustible  materials.
NOTE  A  3/8"  gap  above  the  face  is  required  for  face  installation  and  removal.