Avalon Stoves 21 DV Fireplace Manuale Utente

Pagina di 50
Safety Label
43
© Travis Industries
4040830
100-01143
Listing Label
The  safety  (listing)  label  is  attached  to  the  operating  tag  (chained  to  the  fireplace  near  the  gas
control  valve).    A  copy  is  shown  below
Bed & Breakfast
V
ented Gas 
Fireplace Heater
Report No. 028-S-53-5
Certified for USA
Tested to: 
ANSI Z21.88b-2001 “V
ented Gas Fireplace Heater” and UL
307b-1995 “Gas Burning Heating 
Appliances
for Manufactured Homes”.
VENTED GAS FIREPLACE HEA
TER – NOT FOR USE WITH SOLID FUEL
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,
ANSI Z223.1.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is
desired, the optional factory conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owner
’s manual for
details. This appliance is not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
W
ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property 
damage. Refer to the owner
’s information manual provided with this appliance. For assistance or additional 
information consult a qualified installer
, service agency or the gas supplier
.
W
ARNING: Operation of this appliance when not connected to a properly installed and maintained venting 
system or tampering with the blocked vent shutoff system can result in carbon monoxide (CO) poisoning and 
possible death.  
CAUTION: Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s)
should be done by a licensed or qualified service person.
CAUTION: Hot while in operation. Do not touch. Keep children, clothing, furniture, gasoline and other liquids
having flammable vapors away
.
This appliance must be properly connected to a venting system in accordance with the manufacturer
’s installation
instructions. Use only approved coaxial direct vent system to vent this appliance to the exterior
. See owner
’s 
manual for approved brands of venting.
10850 1
17th Pl. N.E. Kirkland, W
A
 98033
Minimum Clearances to Combustibles
Stove to Side, Back and T
op
..............
1/2”
Decorative Front to W
ood Facing
...........
1/8”
Stove to Bottom
..................................
0”
Decorative Front to 12” Deep Mantle
......
8”
Decorative Front to Sidewall
...................
1/2”
L.P
.
N.G.
L.P
.
N.G.
Input Rate on “HI” (BTU/Hr) . . . . . . .
16,500
16,500
Minimum Inlet Pressure (inches W
.C.)
 . . . . . . . .
11”
5.5”
Input Rate on “LO” (BTU/Hr)
 . . . . . .
13,400
14,500
Manifold Pressure on “HI” (inches W
.C.)
 . . . . . .
10”
3.5”
This appliance is equipped only for altitudes 0-2000 ft. (0-610 m).
Electrical Rating:
115v
, 1.5 
Amps, 60 Hz
Manufacture
2002
Jan.
Apr
.
Jul.
Oct.
Date:
2003
Feb.
May
Aug.
Nov
.
2004
Mar
.
Jun.
Sep.
Dec.
IGN   0479